Product Information

Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00[Product print page]

Product Name: Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00
Product Type: NFLF111-S50/F9S00
Exhibitors: ONO SOKKI
Product Documentation: No Related Documents

Brief

Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00, Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00. Yokogawa STARDOM. Favorable Price. Please contact us: tekrachel @ 163.com


 Detailed description

Manufacturer: Yokogawa Electric Corporation

STARDOMFCN, FCN-500, FCN-100, FCN-RTU, FCJ

Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00  

The Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00 is installed in an FCN (field control node) autonomous controller. The Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00 functions as a link master (LM) device capable of controlling communication schedules on the H1 fieldbus segment connected to each of its port and performs data exchange between the FCN and fieldbus devices.

General Specifications for Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00

Item

Specifications

Model

NFLF111(*1)

Interface

Foundation fieldbus H1

Ports

4 ports per module

Baud rate

31.25 kbps

Functions

Link active scheduler (LAS)

functionality

Power

Power supply voltage (*2)

5 V DC ± 5 %

Maximum current dissipation

0.5 A

Bus connection

Pressure clamp terminals (*2)

Indicators

LED status indicators

Installation

To be installed in a base module.

Weight

0.4 kg

Size

Dimensions

32.8 x 130.0 x 127.5 mm

(W x H x D)

Occupying slots

1

Isolation

Field-to-system isolated with a withstanding voltage up to 1500

V AC for 1 minute

Redundancy

FCN-500, FCN-100

Available (*3) (*4)

FCN-RTU

Unavailable

Number of modules

FCN-500, FCN-100

Up to 8 or 8 duplexed pairs of

NFLF111

FCN-RTU

Up to 8

Number of FF BlockViews

Up to 100 blocks per NFLF111 (*5)

Up to 800 blocks per FCN

Inputs/outputs

48 points per port

Linkable fieldbus devices

16 devices per port

*1: Can also be installed in an extension unit of Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00.
*2: Needs a pressure clamp terminal block (below) to be installed. The block has built-in terminators that can be switched on and off individually.

Model and Suffix Codes for Yokogawa Foundation Fieldbus Communication Module NFLF111-S50/F9S00

Description

Model

NFLF111

Foundation fieldbus communication module

Suffix

Codes

-S

Standard type

5

With no explosion protection

E

With explosion protection

0

Basic type

1

With ISA Standard G3 option

4

With Extended Temperature range

( -40 to +70 ˚C) option

5

With Extended Temperature range

( -40 to +70 ˚C) and ISA Standard G3 option

Option

Codes

/F9S00

With pressure clamp terminal block for Foundation fieldbus (Model: NFTF9S-00)

NFTF9S Pressure Clamp Terminal Block for Foundation fieldbus

Description

Model

NFTF9S

Pressure clamp terminal block for

Foundation fieldbus (for NFLF111)

Suffix

Codes

-0

Without surge absorber

0

Always 0