Product Information

Yokogawa Duplexed Field Control Unit AFV30D-A41462[Product print page]

Product Name: Yokogawa Duplexed Field Control Unit AFV30D-A41462
Product Type: AFV30D-A41462
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Duplexed Field Control Unit AFV30D-A41462


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Duplexed Field Control Unit AFV30D-A41462

Standard Specifications

Memory Protection During Power Failure
Battery
Battery Back-up for Main Memory: Max. 72 hours
Battery Recharge Time: Min. 48 hours
Communication Interface
Vnet/IP Interface: Dual-redundant
HKU Interface (Option)
When option code /HKU is specified, a FCU fault contact is output from the HKU. Also, the environmental conditions of the cabinet connected via the HK bus and optical ESB bus can be monitored and the operating status of the HKU can be displayed on the HIS. System alarms can also be displayed.
No. of Node Units Connectable
Max. 13/FCU    Yokogawa Duplexed Field Control Unit AFV30D-A41462
The total number of ESB Bus Node Units (ANB10) and Optical ESB Bus Node Units (ANB11) that can be connected to FCU are 13 or less.
Module Configuration
Power Supply Module (PW481, PW482, or PW484): 2 modules for dual-redundant configuration.
Processor Module (CP471 or CP461): 2 modules for dual-redundant configuration. A dual-redundant configuration is enabled by using 2 identical modules with same model code (CP471 or CP461).
I/O Module (*1): Max. 8
*1: Non-standard component.
Power Supply
Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC
Specify with the Suffix Code.
Weight
Approx. 7.0 kg (AFV30S) 

Approx. 8.0 kg (AFV30D)
Yokogawa Duplexed Field Control Unit AFV30D-A41462

Models and Suffix Codes

Field Control Unit

Description

Model

AFV30S

Field Control Unit (for FIO, 19-inch Rack Mountable)

Suffix

Codes

-A

Standard type (for CP471) (*1)

-S

Standard type (for CP461) (*3)

3

Dual-redundant Vnet/IP, single power supply

4

Dual-redundant Vnet/IP, dual-redundant power supply

1

Always 1

1

100 - 120 V AC power supply (*4)

2

220 - 240 V AC power supply (*4)

4

24 V DC power supply (*4)

   0

Basic type (*5)

   1

With ISA Standard G3 option (*5)

   5

Basic type with no explosion protection

   6

With ISA Standard G3 option and no explosion protection

   E

Basic type with explosion protection

   F

With ISA Standard G3 option and explosion protection

1

LFS1700 Control function for field control station

(for AFV30¨/AFV40¨, Vnet/IP and FIO) (for CP461) (*6)

2

Always 2 (R6.01 or later)

Option

Codes

/HKU

With HKU interface (*7)

/ATDOC

Explosion Protection Manual (*8)

/MRN

With Marine Standards (*2)

Yokogawa Duplexed Field Control Unit AFV30D-A41462

Duplexed Field Control Unit

Description

Model

AFV30D

Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable)

Suffix

Codes

-A

Standard type (for CP471) (*1)

-S

Standard type (for CP461) (*3)

4

Dual-redundant Vnet/IP, dual-redundant power supply

1

Always 1

1

100 - 120 V AC power supply (*4)

2

220 - 240 V AC power supply (*4)

4

24 V DC power supply (*4)

   0

Basic type (*5)

   1

With ISA Standard G3 option (*5)

   5

Basic type with no explosion protection

   6

With ISA Standard G3 option and no explosion protection

   E

Basic type with explosion protection

   F

With ISA Standard G3 option and explosion protection

1

LFS1700 Control function for field control station

(for AFV30¨/AFV40¨, Vnet/IP and FIO) (for CP461) (*6)

2

Always 2 (R6.01 or later)

Option

Codes

/HKU

With HKU interface (*7)

/ATDOC

Explosion Protection Manual (*8)

/MRN

With Marine Standards (*2)

Yokogawa Duplexed Field Control Unit AFV30D-A41462