Product Name: Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN
Product Type: EJA110E-DFS5J-912NN
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN, Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN, used to measure the pressure or level of industrial liquids and gases.


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN

The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family of pressure transmitters. Released in 2012, it combines the ruggedness and success of the work-horse EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN

The EJA110E is Yokogawa's standard traditional-mount differential pressure transmitter in this series.

EJA110E features include:

Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN

0.055% Accuracy (0.04% Accuracy option)
0.1% Stability for 7 years
Exida and TUV SIL 2 / SIL3 Certified
90 msec Response Time
MWP 2,300 psi (MWP 3,600 psi option)

Local Parameter Setting (LPS)

Model and Suffix Codes

Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN

Model

Suffix Codes

Description

EJA110E

. . . . . . . . . . . . . . . . . . .

Differential pressure transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . . . 

-J . . . . . . . . . . . . . . . . . . . . . 

-F . . . . . . . . . . . . . . . . . . . . 

 -G . . . . . . . . . . . . . . . . . . . . . .

 -Q . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5/HART 7protocol)*1

Digital communication (FOUNDATION Fieldbus protocol, referto GS 01C31T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to GS01C31T04-01EN)

Low Power, 1 to 5 V DC with digital communication (HART 7protocol)

Measuremenspan (capsule)

F . . . . . . . . . . . . . . . . . . . . 

 L . . . . . . . . . . . . . . . . . . . . . .

 M . . . . . . . . . . . . . . . .

H . . . . . . . . . . . . . . . .

V . . . . . . . . . . . . . . . . .

0.5 to 5 kPa (2.0 to 20 inH2O) (For Wetted parts material codeS)

0.5 to 10 kPa (2.0 to 40 inH2O) (For Wetted parts material codeM, H, T, A, D and B)

1 to 100 kPa (4 to 400 inH2O)

5 to 500 kPa (20 to 2000 inH2O)

0.14 to 14 MPa (20 to 2000 psi)

Wetted partmaterial *2

 . . . . . . . . . . . . . . . 

Refer to Wetted Parts Material Table.

Process connections

 

 

 

0 . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . .

2 . . . . . . . . . . . . .

3 . . . . . . . . . . . . .

4 . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . 

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connecto

with Rc1/2 female process connecto

with 1/4 NPT female process connecto

with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts materia

J . . . . . . . . . . . .

G. . . . . . . . . . . .

C . . . . . . . . . . . .

B7 carbon steel

316L SST

660 SST

Installation

 

-7 . . . . . . . . . . . . . . ..

-8 . . . . . . . . . .

-9 . . . . . . . . . .

-B . . . . . . . . . .

-U . . . . . . . . . .

Vertical piping, left side high pressure, and process connectiondownside

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Bottom Process Connection, left side high pressure*3

Universal flange*3

Amplifier housing

1 . . . . . . . . .

3 . . . . . . . . .

2 . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties*5

ASTM CF-8M stainless steel*6

Electrical connection

0 . . . . . . .

2 . . . . . . . . . . ..

4 . . . . . . .

5 . . . . . . .

7 . . . . . . . . . .

9 . . . . . . .

A . . . . . . . . . .

C . . . . . . . . .

 D . . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plug

M20 female, two electrical connections without blind plugG1/2female, two electrical connections and a blind plug*7

1/2 NPT female, two electrical connections and a blind plug*7

M20 female, two electrical connections and a blind plug*7

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blindplug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

 

D . . . . .

E . . . . . . . . 

N . . . . . .

Digital indicator*8

Digital indicator with the range setting switch (push button)*9

None

Mounting bracket                                   ►

B . . . . . 

D . . . . . 

J . . . . . 

K . . . . . 

 M . . .


N . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST or SCS13A 2-inch pipe mounting, L type (for verticalpiping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST or SCS14A 2-inch pipe mounting, L type (for verticalpiping)

316 SST 2-inch pipe mounting (for bottom process connectiontype

None

Optional Codes

¨/ Optional specification

The “►” marks indicate the most typical selection for each specification.

*1:      HART 5 or HART 7 is selectable. Specify upon ordering.

*2:      Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Yokogawa Differential Pressure Transmitter EJA110E-DHS5J-912NA

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*3:      Only applicable for Wetted parts material code S.

*4:      Not applicable for measurement span code F.

*5:      Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less. Yokogawa Field Instrument DPharp Pressure Transmitter EJA110E-DFS5J-912NN

*6:      Not applicable for electrical connection code 0, 5, 7 and 9.

*7:      Material of a blind plug is aluminum alloy or 304 SST.

*8:      Not applicable for output signal code G.

*9:      Not applicable for output signal code F.