Specifications - Time Constant / Response: 9 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 751:1983, Amendments 1 and 2 - Insulation Resistance: 1,000 MΩ minimum insulation resistance when measured at 500 Vdc and at room temperature - Calibration Options: IEC 751 Class A accuracy; Calibration schedule with Callendar-Van Dusen constants; MID custody transfer calibration
Emerson Rosemount RTD Temperature Sensor 0065N31J0150N0710 Features - Industry-standard sensor per IEC 751 with single or dual element design offers reliable and flexible performance - Resilient sensor withstands high vibration industrial applications - DIN-style sensor connection heads allow for quick mounting and replacement - Sensor selections cover a wide range of temperatures from –321 to 1112°F (–196 to 600°C) to meet process demands - Terminal block, flying leads and spring-loaded threaded adapters enable remote or integral mounting configuration - Callendar-Van Dusen constants allow for transmitter-sensor matching and provide the highest level of accuracy - Optional Class A accuracy ensures critical temperature measurement points meet tolerance standards and accuracy - Option for thermowell assembly increases protection from corrosive environments - Measurement Instrument Directive (MID) calibration options for custody transfer applications - Global hazardous location approvals meet local requirements
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel