Manufacturer: Yokogawa Electric Corporation
Yokogawa MIL Connector Cable KMS50-015
MIL connector cables and MIL connector terminal blocks enabling connections to field control node (FCN) autonomous controllers.
MIL Connector Cables (KMS40 and KMS50) / MIL Connector Terminal Blocks (TAS40 and TAS50) These MIL connector cables and connector terminal blocks are MIL connector-equipped (MIL-C-83503-compliant) cables and connectors. Using these cables and terminal blocks makes it possible to reduce wiring connections for switchboard design. Note: KMS40 should be used with TAS40. KMS50 should be used with TAS50.
Combination of I/O Modules with MIL Connector Cable / MIL Connector Terminal Block I/O modules can be used in combination with MIL connector cables and MIL connector terminal blocks, as given below. Table Combinations of I/O Modules Yokogawa MIL Connector Cable KMS50-015
Model
Module name
MIL connector terminal block (*1)
Cable
Terminal block
CPU Module
NFCP050
CPU Module for FCN-RTU (1 to 5V Input: 12-Channel, 4 to 20 mA Output:
2-Channel, Status input: 16-Channel, Status output: 16-Channel, Pulse input: 2-Channel, Non-Isolated)
KMS40 (*3)
TAS40 (*3)
Analog I/O Modules
NFAI141
Analog Input Module (4 to 20 mA, 16-Channel, Non-Isolated)
KMS40
TAS40
NFAV141
Analog Input Module (1 to 5 V: differential input, 16-Channel, Non- Isolated)
NFAV142
Analog Input Module (-10 V to +10 V, 16-Channel, Non-Isolated)
NFAV144
Analog Input Module (-10 V to +10 V, 16-Channel, Isolated)
NFAI841
Analog I/O Module (4 to 20 mA Input, 4 to 20 mA Output, 8-Channel
Input/8-Channel Output, Non-Isolated)
NFAB841
Analog I/O Module (1 to 5 V input: differential input, 4 to 20 mA Output,
8-Channel Input/8-Channel Output, Non-Isolated)
NFAV542
Analog Output Module (-10 V to +10 V, 16-Channel, Non-Isolated)
NFAV544
Analog Output Module (-10 V to +10 V, 16-Channel, Isolated)
NFAI143
Analog Input Module (4 to 20 mA, 16-Channel, Isolated)
NFAI543
Analog Output Module (4 to 20 mA, 16-Channel, Isolated)
NFAT141
Thermocouple/mV Input Module (*1) (16-Channel, Isolated)
KMS40 (*2)
TAS40 (*2)
NFAI135
Analog Input Module (4 to 20 mA, 8-Channel, Isolated Channels)
NFAI835
Analog I/O Module (4 to 20 mA, 4-Channel Input/4-Channel Output, Isolated Channels)
NFAP135
Pulse Input Module (8-Channel, Pulse Count, 0 to 10 kHz, Isolated
Channels)
NFAF135
Frequency Input Module (8-Channel, contact ON/OFF, Voltage pulse,
0.1 Hz to 10 kHz, Isolated Channels)
Digital I/O Modules
NFDV151
Digital Input Module (32-Channel, 24 V DC)
KMS50
TAS50
NFDV161
Digital Input Module (64-Channel, 24 V DC)
KMS50 (*3)
TAS50 (*3)
NFDV532
Pulse Width Output Module (4-channel : Up Pulse/Down Pulse, 24 V DC, Isolated)
NFDV551
Digital Output Module (32-Channel, 24 V DC)
NFDV561
Digital Output Module (64-Channel, 24 V DC)
Model and Suffix Codes
MIL Connector Terminal Block
Description
(40- pole plug type, M3.5)
(50- pole plug type, M3.5)
Suffix Codes
-0N
Standard type
MIL Connector Cable
(40-pole plug type)
(50-pole plug type)
-005
Cable length 0.5m
-010
Cable length 1.0m
-015
Cable length 1.5m
-020
Cable length 2.0m
-025
Cable length 2.5m
-030
Cable length 3.0m
-040
Cable length 4.0m
-050
Cable length 5.0m
-060
Cable length 6.0m
-070
Cable length 7.0m
-080
Cable length 8.0m
-090
Cable length 9.0m
-100
Cable length 10.0m
-150
Cable length 15.0m
-200
Cable length 20.0m
-250
Cable length 25.0m
MIL Cable Connector Cover
NFCCC01
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel tekrachel@163.com
Add.: Room 2401 Building D Greenland Central Plaza, Science City, Huangpu District, Guangzhou 510663, Guangdong Province, China.