Product Information

Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1[Product print page]

Product Name: Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1
Product Type: EJA430E-JBS5C-91DDB/KU22/X2/D3/T1
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1, Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1

The high performance gauge pressure transmitter EJA430E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam pressure. The EJA430E outputs a 4 to 20 mA DC signal corresponding to the measured pressure. Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1
It also features quick response, remote setup and monitoring via BRAIN or HART communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1
All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement. Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1


Model and Suffix Codes

Yokogawa Gauge Pressure Transmitter EJA430E-JBS5C-91DDB/KU22/X2/D3/T1

Model

Suffix Codes

Description

EJA430E

. . . . . . . . . . . . . . . . . . . . .

Gauge pressure transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . .

-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 -G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 -Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1

Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to GS 01C31T04-01EN)

Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)

Measurement span (capsule)

H . . . . . . . . . . . . . . . . .

A . . . . . . . . . . . . . . . . .

B . . . . . . . . . . . . . . . . . .

5 to 500 kPa (20 to 2000 inH2O)

0.03 to 3.5 MPa (4.3 to 500 psi)

0.14 to 16 MPa (20 to 2300 psi)

Wetted parts material *2

¨ . . . . . . . . . . . . . . . . .

Refer to Wetted Parts Material Table.

Process connections

 

 

 

0 . . . . . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . . . . .

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connecto

with Rc1/2 female process connecto

with 1/4 NPT female process connector

with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts materia

J . . . . . . . . . . . .

G. . . . . . . . . . . . .

C . . . . . . . . . . . . 

B7 carbon steel

316L SST

660 SST

Installation

 

 

-3 . . . . . . . . . . . . . . . .


-7 . . . . . . . . . . . . . . . .


-8 . . . . . . . . . .

-9 . . . . . . . . . . .

-B . . . . . . . . . . .

-U . . . . . . . . . . .

Vertical piping, right side high pressure, and process connection down sid

Vertical piping, left side high pressure, and process connection down sid

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Bottom Process Connection, left side high pressure*3

Universal flange*3

Amplifier housing

1 . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . .


2 . . . . . . . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties *4

ASTM CF-8M stainless steel *5

Electrical connection

0 . . . . . . .. . . . . . .. . . . . . .


2 . . . . . . . . . . . . . . . . .. . . . . . .


4 . . . . . . . . . . . . . . . .


5 . . . . . . .. . . . . . .. . . . . . .. . . . . .

7 . . . . . . . . . . . .. . . . . . .. . . . . . .


9 . . . . . . .. . . . . . .. . . . . . .. . . . . . .


A . . . . . . . . . . . .. . . . . . .. . . . . . .


C . . . . . . . . . . .. . . . . . .. . . . . . .


D . . . . . . .. . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plug

M20 female, two electrical connections without blind plug

G1/2 female, two electrical connections and a blind plug *6

1/2 NPT female, two electrical connections and a blin plug*6

M20 female, two electrical connections and a blind plug *6

G1/2 female, two electrical connections and a 316 SST blind plug

1/2 NPT female, two electrical connections and a 316 SST blind plug

M20 female, two electrical connections and a 316 SST blind plug

Integral indicator

 

D . . . . .

E . . . . .

N . . ........

Digital indicator *7

Digital indicator with the range setting switch (push button*8

None

Mounting bracket                                   ►

B . . . . . .. . . . . . .. . . . . . .


D . . . . . .. . . . . . .. . . . . . .


J . . . . . . . . . . . . .. . . . . . .


K . . . . . . . . . . . .. . . . . . .

M . . . . . . . . . . .. . . . . . ..


N . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST or SCS13A 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting (for bottom proces connection type

None

Optional Codes

¨/ Optional specification