Product Information

Yokogawa Polymer Electrolyte pH Sensor PH4PT[Product print page]

Product Name: Yokogawa Polymer Electrolyte pH Sensor PH4PT
Product Type: PH4PT
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Polymer Electrolyte pH Sensor PH4PT, Yokogawa Polymer Electrolyte pH Sensor PH4PT


 Detailed description

Yokogawa Polymer Electrolyte pH Sensor PH4PT       


Yokogawa’s line of pH sensors has been strengthened by the inclusion of the polymer electrolyte pH sensor PH4P/PH4PT, HF-resistant pH sensor PH4F/PH4FT, pH sensor for chemical process PH4C /PH4CT, and pH sensor for fermentation PH4FE. Like the pH sensor series, the ORP sensor series is also offered as a complete lineup with the polymer electrolyte ORP sensor OR4P, ORP sensors for chemical process OR4C in addition to standard Ryton pH/ORP sensors. Yokogawa Polymer Electrolyte pH Sensor PH4PT


PH4/OR4 Sensor Series allows pH/ORP measurement under severe conditions, such as where the process fluid is heavily contaminated or contains sulfide. Yokogawa Polymer Electrolyte pH Sensor PH4PT


PH4P Polymer Electrolyte pH Sensor
PH4PT Polymer Electrolyte pH Sensor with RTD
 (resistance temperature detector)
OR4P Polymer Electrolyte ORP Sensor
PH4F HF-Resistant pH Sensor
PH4FT HF-Resistant pH Sensor with RTD
 (resistance temperature detector)
PH4C pH sensor for Chemical Process
PH4CT pH sensor for Chemical Process with RTD
 (resistance temperature detector)
OR4C ORP sensor for Chemical Process
PH4FE pH sensor for Fermentation
Features

Yokogawa Polymer Electrolyte pH Sensor PH4PT

Polymer Electrolyte pH Sensor PH4P, PH4PT, OR4P
• Allows pH/ORP measurement under severe conditions, such as where the process fluid is heavily contaminated or contains sulfide ion.
• With polymer used as the inner solution, the liquid junction is large (around 1.0 mm), and there are 2 single pores, which prevent clogging.
• pH sensor with RTD (resistance temperature detector) PH4PT is also available.


HF-Resistant pH Sensor PH4F, PH4FT
• The special sensing membrane allows measurement of solutions or drainage containing hydrofluoric acid.
• With polymer used as the inner solution, the liquid junction is large (around 1.0 mm), and there are 2 single pores, which prevent clogging.
• pH sensor with RTD PH4FT is also available.


pH/ORP sensor for Chemical Process PH4C, PH4CT, OR4C
Yokogawa Polymer Electrolyte pH Sensor PH4PT

• Extremely long life span for pH measurement in electrolytic process.
• With the pressurized inner solution, a pressure holder is not needed.
• pH sensors with RTD, PH4CT is also available.
• The reference electrode is composed of silver ion trap which inhibits the generation of sulfide around the ceramic liquid junction.


pH sensor for Fermentation PH4FE
• Inner solution can be refilled.
• There are 3 of ceramic liquid junctions.
• The reference electrode is composed of silver ion trap which inhibits the generation of sulfide around the ceramic liquid junction.