Yokogawa Air Set K9473XK
General specifications
6. ZO21R Probe Protector
Used when sample gas flow velocity is approx. 10m/ sec or more and dust particles wears the detector in cases such as pulverized coal boiler of fluidized bed furnace (or burner) to protect the detector from wearing by dust particles.
7. ZO21S Standard Gas Unit (*)
Standard Gas Unit must not be located in hazardous area.
Function: Portable unit for calibration gas supply consisting of span gas (air) pump, zero gas cylinder with sealed inlet, flow rate checker and flow rate needle valve.
Sealed Zero Gas Cylinders (6 provided): E7050BA
Weight: Approx. 3 kg
8. ZA8F Flow Setting Unit
Used when instrument air is provided.
Weight: Approx. 2.3 kg
Yokogawa Air Set K9473XK
9. ZR40H Automatic Calibration Unit for Separate type Oxygen Analyzer
Automatic Calibration Unit must be located in Non- hazardous area.
Used when automatic calibration is required for the separate type and instrument air is provided. The solenoid valves are provided as standard.
Power Supply: 24 V DC (from ZR402G)
Weight: Approx. 3.5 kg
Yokogawa Air Set K9473XK
10. Automatic Calibration Unit for Integrated type Oxygen Analyzer
When Automatic Calibration of (-A) or (-B) code is specified, Automatic Calibration Unit is installed in the ZR202S.
Only Automatic Calibration Unit is not available.
11. L9852CB/G7016XH Stop Valve
The stop valve and the nipple are mounted on the calibration gas line.
The nipple is used to connect the stop valve. They are attached when the option code (/SV) is selected for the ZR22S or the ZR202S.
Connection: Rc1/4 (L9852CB) or 1/4 NPT (F) (G7016XH)
Material: SUS316 (JIS) Weight: Approx. 80 g
12. K9292DN/K9292DS Check Valve
This is used to prevent entry of sample gas into calibration gas line. Purpose is the same as stop valve, but is convenient, as it does not need to be opened or closed for calibration.
Mount directly on calibration gas inlet of detector in place of stop valve. However as source pressure of 150 kPa G or more is needed, standard gas unit cannot be used. When option code “/CV” of the ZR22S or the ZR202S is specified, check valve is provided.
Connection: Rc1/4 (K9292DN) or 1/4 NPT (F) (K9292DS)
Weight: Approx. 40g
Yokogawa Air Set K9473XK
13. Air Set
This set is used to lower the pressure when instrument air is used as the reference and span gases.
G7003XF/K9473XK
Weight: Approx. 1 kg
G7004XF/K9473XG
Weight: Approx. 1 kg
14. G7013XF/G7014XF Pressure Regulator
Primary Pressure: 14.8 MPa G, Secondary Pressure: 0 to 0.4 MPa G
15. ZR22A, ZR202A Heater Assembly
ZR22A: Spare Parts for ZR22S
ZR202A: Spare Parts for ZR202S
16. E7044KF Case Assembly of Calibration Gas Cylinder
Weight: Approx. 10 kg with gas cylinder
Yokogawa Air Set K9473XK
Model and Suffix Codes
Automatic Calibration Unit for Separate type Oxygen Analyzer
Model
|
Suffix code
|
Option code
|
Description
|
ZR40H
|
- - - - - - -
|
- - - -
|
Automatic calibration
unit for ZR402G
|
Gas piping connection
|
-R
-T
|
- - - - - -
|
Rc1/4
1/4 NPT (F)
|
Wiring
connection
|
-P
-G
-M
-T
|
- - - - - -
- - - - - -
|
Pipe connection (G1/2)
Pg 13.5
M20 x 1.5
1/2 NPT
|
─
|
-A
|
- - - -
|
Always -A
|