Yokogawa Gas Density Detector GD40G
General purpose detector. 1/4 NPT gas threads and 1/2 NPT gland threads. No cable gland included. Mounting hardware included.
The Gas Density Meter consists of gas density converter GD402 and gas density detector GD40.
The Model GD402 gas density converter and Model GD40 detector not only provide continuous measurement of gas density, but also several other valuable parameters, including specific gravity and molecular weight. The GD40 detector is designed for intrinsically safe and explosion-proof, explosion protected applications. It is designed to be virtually maintenance free for all accepted applications.
The Model GD402 is a rugged microprocessor- based converter designed in two versions to meet both general area and explosion-proof application requirements. In addition to the display of several key data items, the converter also provides the choice of three different means for calibration: automatic; semi- automatic and one-touch manual operation.
Features
Yokogawa Gas Density Detector GD40G
• Proven design
Highly responsive and sensitive measurement
of density. Specific gravity, molecular weight and gas concentration can also be displayed using Yokogawa's gas density analyzing techniques.
• Detector features
1. Resistant to external vibrations.
2. Outstanding stability against sudden changes in gas temperature.
3. The multi-mode self-oscillation circuit minimizes drift caused by the sensor itself or by oil mist, dust, moisture, etc. sticking to the sensor.
4. Easy cleaning and regeneration of sensor.
Should the sensor be contaminated with dust and/ or mist, then it can be easily cleaned and returned to its original condition.
5. Only routine maintenance is required.
(for example, once per 3 months depending on application.)
• Simple, user-friendly interface
Configuration can be performed locally via the front panel or remotely by using the (optional) "Brain" terminal.
• Low installation cost
Both explosion-proof and general purpose converters are designed for easy mounting on a pipe. Wiring between the detector and converter is based on a two-wire system, keeping installation cost to a minimum.
General Specification
Yokogawa Gas Density Detector GD40G
1.1 System Components
(1) GD40G,T,V,R detector : Rainproof for outdoor use
(equivalent to IP65/NEMA 4X)
(see note under “2.2 Ambient condition” on page 3.) Ambient Temperature : -10 to 60°C
Ambient Humidity : 5 to 95%RH
GD40G : General purpose detector. (Non-Explosion-proof)
Electrical connection : 1/2 NPT female
Process connection : 1/4 NPT female
GD40T : FM Explosion-proof and Intrinsically safe
Approval.
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G with Intrinsically Safe sensor for Class I, II, III, Division 1, Groups B, C, D, E, F and G.
Enclosure : NEMA Type 4X Temperature Code : T5
Electrical connection : 1/2 NPT female
Process connection : 1/4 NPT female
GD40V : CSA Explosion-proof and Intrinsically safe Approval.
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G with Intrinsically Safe sensor for Class I, II, III, Division 1, Groups B, C, D, E, F and G.
Enclosure : Type 4X Temperature Code : T5
Electrical connection : 1/2 NPT female
Process connection : 1/4 NPT female
GD40R : TIIS Explosion-proof and Intrinsically safe Approval.
Explosion-proof code : Exd [ia] IIB+H2T5
Temperature Code : T5
Electrical connection : G1/2 female
Process connection : Rc1/4
(2) GD402G, T, V, R Converter : Rainproof for outdoor use
(equivalent to IP65 / NEMA 4X) Ambient Temperature : -10 to 55°C Ambient Humidity : 5 to 95%RH
GD402G: General purpose converter. (Non- Explosion-proof)
Electrical connection : 21mm (0.9inch) in diameter. Pg13.5 cable glands included
GD402T : FM Explosion-proof Approval.
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Enclosure : NEMA Type 4X Temperature Code : T6
Electrical connection : 1/2 NPT female
Yokogawa Gas Density Detector GD40G
GD402V : CSA Explosion-proof Approval.
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Enclosure : Type 4X
Temperature Code : T6
Electrical connection : 1/2 NPT female
GD402R : TIIS Explosion-proof Approval.
Explosion-proof code : Exd IIB+H2T6
Temperature Code : T6
Electrical connection : G3/4 female
(3) EJA310 Absolute press transmitter (optional) FM Explosion-proof Approval:
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Hazardous(classified locations, indoors and outdoors (NEMA 4X)
Temperature Code : T6
Ambient Temperature : -40 to 60°C Ambient Humidity : 5 to 100%RH (at 40°C)
Electrical connection : 1/2 NPT female
Process connection : 1/4 NPT female
CSA Explosion-proof Approval:
Explosion-proof for Class I, Division 1, Groups B, C and D;
Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Division 2 ‘SEALS NOT REQUIRED’ Enclosure : Type 4X
Temperature Code : T4, T5, T6
Max. Process Temp.: T4 120°C, T5
100°C, T6 85°C
Ambient Temperature : -40 to 80°C Ambient Humidity : 5 to 100%RH (at 40°C)
Electrical connection : 1/2 NPT female
Process connection : 1/4 NPT female
TIIS Explosion-proof Approval:
Explosion-proof code : Ex do IIC T4X Temperature Code : T4
Ambient Temperature : -20 to 60°C Ambient Humidity : 5 to 100%RH (at 40°C)
Electrical connection : G1/2 female
Process connection : Rc1/4
Model and Suffix Codes
Yokogawa Gas Density Detector GD40G
1.Gas Density Converter
Model
|
Suffix code
|
Option code
|
Description
|
GD402G
|
- - - - - - - - - - - - -
|
- - - - - - - - - - -
|
General purpose model, 6 cable glands included.
|
GD402T
|
- - - - - - - - - - - - -
|
- - - - - - - - - - -
|
FM certified explosion proof model. Gland threads 1/2 NPT. No cable glands included.
|
GD402V
|
- - - - - - - - - - - - -
|
- - - - - - - - - - -
|
CSA certified explosion proof model. Gland threads 1/2 NPT. No cable glands included.
|
GD402R
|
- - - - - - - - - - - - -
|
- - - - - - - - - - -
|
TIIS certified explosion proof model. Gland threads G3/4. No cable glands included.
|
Power supply
|
-D
-A
|
- - - - - - - - - - -
- - - - - - - - - - -
|
24 V DC
100-240 V AC
|
Label and approval
|
-E
-J
|
- - - - - - - - - - -
- - - - - - - - - - -
|
English label
TIIS approval, English label (only GD402R)
|
Instruction Manual
|
-E
|
- - - - - - - - - - -
|
English
|
Options
(only GD402G)
|
/PA
/U
/H
|
Panel mounting
Universal (Pipe and Wall) Mounting
Hood
|
|
|
|
|
|
|
Note1: Explosion-proof models, GD402T, V, R have only pipe mounting hardware as standard.
Note2: In the case of GD402R,where cables enter into the converter, cable glands specified
in cl.3 shall be used.
GD402¨ Standard Accessory
List
Model
|
Item
|
Qty
|
Part Number
|
GD402G
|
Fuse
|
1
|
A1109EF (Power Supply: 100-240 V AC) A1111EF (Power Supply: 24 V DC)
|
Universal Mount Set
|
1
|
K9171SS
|
Panel Mount Set
|
1
|
K9171ST
|
GD402R GD402T GD402V
|
Fuse
|
1
|
A1512EF (Power Supply: 100-240 V AC) A1111EF (Power Supply: 24 V DC)
|
Bracket
|
1
|
K9214HD
|
Bracket
|
1
|
K9214HE
|
U-Bolt Assy
|
2
|
D0117XL-A
|
Bolt
|
1
|
Y9835NU
|
Bolt
|
2
|
Y9820NU
|
2-1. Gas Density Detector
Model
|
Suffix code
|
Option code
|
Description
|
GD40G
|
- - - - - - - - - - - - -
|
- - - - - - - - - - - -
|
General purpose detector. 1/4 NPT gas threads and 1/2 NPT gland threads. No cable
gland included. Mounting hardware included.
|
GD40R
|
- - - - - - - - - - - - -
|
- - - - - - - - - - - -
|
TIIS certified explosion proof detector. Rc1/4 gas threads and G1/2 gland threads.
Cable gland included. Mounting hardware included.
|
Label approval
|
-E
-J
|
- - - - - - - - - - - -
- - - - - - - - - - - -
|
English label, no approval (only GD40G)
TIIS approval, English label (only GD40R)
|
Options
|
/EJAJ1
/EJAJ1T
/EJAF2
/EJAF2T
|
TIIS certified EJA mounted with detector on mounting plate. Rc1/4 gas threads and
G1/2 gland thread. Cable gland included.(only GD40R)
TIIS certified EJA mounted with detector on mounting plate. Rc1/4 gas threads and
G1/2 gland thread. Cable gland included. EJA with TAG (only GD40R)
EJA mounted with detector on mounting plate.1/4 NPT gas threads and 1/2 NPT gland
threads. No cable gland included.(only GD40G)
EJA mounted with detector on mounting plate.1/4 NPT gas threads and 1/2 NPT gland
threads. No cable gland included. EJA with TAG (only GD40G)
|
2-2. Gas Density Detector
Model
|
Suffix code
|
Option code
|
Description
|
GD40T
|
- - - - - - - - - - - - -
|
- - - - - - - - - - - -
|
FM certified explosion proof detector. 1/4 NPT gas threads and 1/2 NPT gland thread.
No cable gland included. Mounting hardware included
|
GD40V
|
- - - - - - - - - - - - -
|
- - - - - - - - - - - -
|
CSA certified explosion proof detector. 1/4 NPT gas threads and 1/2 NPT gland thread.
No cable gland included. Mounting hardware included.
|
Options
|
/EJAF3
/EJAF3T
|
FM certified EJA mounted with detector on mounting plate.1/4 NPT gas threads and 1/2
NPT gland thread. No cable gland included. (only GD40T)
FM certified EJA mounted with detector on mounting plate.1/4NPT gas threads and 1/2
NPT gland thread. No cable gland included. EJA with TAG (only GD40T)
|
/EJAF4
/EJAF4T
|
CSA certified EJA mounted with detector on mounting plate. 1/4 NPT gas threads and
1/2 NPT gland thread. No cable gland included. (only GD40V)
CSA certified EJA mounted with detector on mounting plate. 1/4 NPT gas threads and
1/2 NPT gland thread. No cable gland included. EJA with TAG (only GD40V)
|
GD40¨ Standard Accessory
Item
|
Qty
|
Part Number
|
U-Bolt Assy *1
|
4
|
D0117XL-A
|
Bracket *1
|
1
|
K9214HD
|
Bracket *1
|
1
|
K9214HE
|
Gland *2
|
1
|
G9601AM
|
*1: Not supplied when option code "/EJAJ1¨", "/EJAF2¨", "/EJAF3¨" or "/EJAF4¨" is specified.
*2: Supplied only for GD40R.