Product Information

Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4[Product print page]

Product Name: Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4
Product Type: EJA110E-JMS4J-917DB/KU22/M11/T12/D4
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4 Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4


 Detailed description
Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4

The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family of pressure transmitters. Released in 2012, it combines the ruggedness and success of the work-horse EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA110E is Yokogawa's standard traditional-mount differential pressure transmitter in this series.

EJA110E features include:

Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4

0.055% Accuracy (0.04% Accuracy option)
0.1% Stability for 7 years
Exida and TUV SIL 2 / SIL3 Certified
90 msec Response Time
MWP 2,300 psi (MWP 3,600 psi option)

Local Parameter Setting (LPS)


Model and Suffix Codes

Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4

Model

Suffix Codes

Description

EJA110E

. . . . . . . . . . . . . . . . . . .

Differential pressure transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . . . 

-J . . . . . . . . . . . . . . . . . . . . . 

-F . . . . . . . . . . . . . . . . . . . . 

 -G . . . . . . . . . . . . . . . . . . . . . .

 -Q . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1

Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to GS 01C31T04-01EN)

Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)

Measurement span (capsule)

F . . . . . . . . . . . . . . . . . . . . 

 L . . . . . . . . . . . . . . . . . . . . . .

 M . . . . . . . . . . . . . . . .

H . . . . . . . . . . . . . . . .

V . . . . . . . . . . . . . . . . .

0.5 to 5 kPa (2.0 to 20 inH2O) (For Wetted parts material code S)

0.5 to 10 kPa (2.0 to 40 inH2O) (For Wetted parts material code M, H, T, A, D and B)

1 to 100 kPa (4 to 400 inH2O)

5 to 500 kPa (20 to 2000 inH2O)

0.14 to 14 MPa (20 to 2000 psi)

Wetted parts material *2

 . . . . . . . . . . . . . . . 

Refer to Wetted Parts Material Table.

Process connections

 

 

 

0 . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . .

2 . . . . . . . . . . . . .

3 . . . . . . . . . . . . .

4 . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . 

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connecto

with Rc1/2 female process connecto

with 1/4 NPT female process connecto

with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts materia

J . . . . . . . . . . . .

G. . . . . . . . . . . .

C . . . . . . . . . . . .

B7 carbon steel

316L SST

660 SST

Installation

 

-7 . . . . . . . . . . . . . . . .

-8 . . . . . . . . . .

-9 . . . . . . . . . .

-B . . . . . . . . . .

-U . . . . . . . . . .

Vertical piping, left side high pressure, and process connection downside

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Bottom Process Connection, left side high pressure*3

Universal flange*3

Amplifier housing

1 . . . . . . . . .

3 . . . . . . . . .

2 . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties*5

ASTM CF-8M stainless steel*6

Electrical connection

0 . . . . . . .

2 . . . . . . . . . . . .

4 . . . . . . .

5 . . . . . . .

7 . . . . . . . . . .

9 . . . . . . .

A . . . . . . . . . .

C . . . . . . . . .

 D . . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plug

M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*7

1/2 NPT female, two electrical connections and a blind plug*7

M20 female, two electrical connections and a blind plug*7

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

 

D . . . . .

E . . . . . . . . 

N . . . . . .

Digital indicator*8

Digital indicator with the range setting switch (push button)*9

None

Mounting bracket                                   ►

B . . . . .

D . . . . .

J . . . . .

K . . . . .

 M . . .


N . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST or SCS13A 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting (for bottom process connection type

None

Optional Codes

¨/ Optional specification

The “►” marks indicate the most typical selection for each specification.

*1:      HART 5 or HART 7 is selectable. Specify upon ordering.

*2:      Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*3:      Only applicable for Wetted parts material code S.

*4:      Not applicable for measurement span code F.

*5:      Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less.

*6:      Not applicable for electrical connection code 0, 5, 7 and 9.

*7:      Material of a blind plug is aluminum alloy or 304 SST.

*8:      Not applicable for output signal code G.

*9:      Not applicable for output signal code F.



Table. Wetted Parts Materials

Yokogawa Pressure Transmitter EJA110E-JMS4J-917DB/KU22/M11/T12/D4

Wetted parts material code

Cover flange and process connector

 

Capsule

 

Capsule gasket

 

Vent/Drain plug

 

S #

 

ASTM CF-8M *1

Hastelloy C-276 *2 (Diaphragm) F316L SST, 316L SST (Others)

 

Teflon-coated 316L SST

 

316 SST

H #

ASTM CF-8M *1

Hastelloy C-276 *2

PTFE Teflon

316 SST

M #

ASTM CF-8M *1

Monel

PTFE Teflon

316 SST

T

ASTM CF-8M *1

Tantalum

PTFE Teflon

316 SST

A #

Hastelloy C-276 equivalent *3

Hastelloy C-276 *2

PTFE Teflon

Hastelloy C-276 *2

D #

Hastelloy C-276 equivalent *3

Tantalum

PTFE Teflon

Hastelloy C-276 *2

B #

Monel equivalent *4

Monel

PTFE Teflon

Monel

*1:      Cast version of 316 SST. Equivalent to SCS14A.

*2:      Hastelloy C-276 or ASTM N10276.

*3:      Indicated material is equivalent to ASTM CW-12MW.

*4:      Indicated material is equivalent to ASTM M35-2.

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO15156.

Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.