Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13
The high performance Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13 features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.
Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13, its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.
All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
STANDARD SPECIFICATIONS
Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13
|
EJX110A
|
L Capsule
|
M Capsule
|
H Capsule
|
V Capsule
|
Range
|
-40 to 40 inH2O
|
-400 to 400 inH2O
|
-2000 to 2000 inH2O
|
-71 to 2000 psi
|
Span
|
0.4 to 40 inH2O
|
2 to 400 inH2O
|
10 to 2000 inH2O
|
10 to 2000 psi
|
Accuracy
|
±0.04%
|
±0.04%
|
±0.04%
|
±0.04%
|
Accuracy (*Note)
|
|
±0.025% *
|
±0.025% *
|
±0.025% *
|
Degrees of protection
|
IP67, NEMA 4X, and JIS C0920 immersion proof
|
Certificates
|
FM, CENELEC ATEX, CSA, IECEx
|
Output
|
4 to 20 mA DC or FOUNDATION™ fieldbus, 2-wire system with digital communication
|
Supply voltage
|
BRAIN and HART:10.5 to 42 V DC
|
(10.5 to 30 V DC for Intrinsically safe type)
|
Fieldbus:9 to 32 V DC
|
(9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO)
|
Ambient temperature
|
-40 to 85 deg C (-40 to 185 deg F) (general use type)
|
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
|
Process temperature
|
-40 to 120 deg C (-40 to 248 deg F) (general use type)
|
Maximum working pressure
|
2300 psi
|
3600 psi
|
Mounting
|
2-inch pipe mounting
|
Wetted parts material
|
Capsule
|
316L SST(Diaphragm material is Hastelloy C-276),
|
Hastelloy C-276,Tantalum, Monel
|
Cover flange
|
ASTM CF-8M, Hastelloy C-276, Monel
|
Housing
|
Cast aluminum alloy or ASTM CF-8M stainless steel (optional)
|
*Certain conditions apply refer to GS for more information
MODEL AND SUFFIX CODES
Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13
Model
|
Suffix Codes
|
Description
|
EJX110A
|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
Differential pressure transmitter
|
Output signal
|
-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART 5 protocol)
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol) (Refer to GS 01C25T01-01EN)
Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C25T02-01EN)
Digital communication (PROFIBUS PA protocol, refer to
GS 01C25T04-01EN)
|
Measurement span (capsule)
|
F . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
0.1 to 5 kPa (0.4 to 20 inH2O) (For Wetted parts material code S)
0.1 to 10 kPa (0.4 to 40 inH2O) (For Wetted parts material code M, H, T, A, D and B)
0.5 to 100 kPa (2 to 400 inH2O)
2.5 to 500 kPa (10 to 2000 inH2O)
0.07 to 14 MPa (10 to 2000 psi)
|
Wetted parts material *1
|
¨ . . . . . . . . . . . . . . . . . . . . . . . .
|
Refer to “Wetted Parts Material” Table.
|
Process connections
►
|
0 . . . . . . . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . . . . . . . .
|
without process connector (Rc1/4 female on the cover flanges)
with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector
without process connector (1/4 NPT female on the cover flanges)
|
Bolts and nuts materia
|
J . . . . . . . . . . . . . . . . . . . .
G. . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . .
|
B7 carbon steel
316L SST
660 SST
|
Installation
►
|
-7 . . . . . . . . . . . . . . . .
-8 . . . . . . . . . . . . . . . .
-9 . . . . . . . . . . . . . . . .
-B . . . . . . . . . . . . . . . .
-U . . . . . . . . . . . . . . . .
|
Vertical piping, left side high pressure, and process connection downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Bottom Process Connection, left side high pressure*2*3
Universal flange*2
|
Amplifier housing
|
1 . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . .
|
Cast aluminum alloy
Cast aluminum alloy with corrosion resistance properties*4
ASTM CF-8M stainless steel*5
|
Electrical connection
►
|
0 . . . . . . . . . . . .
2 . . . . . . . . . . . .
4 . . . . . . . . . . . .
5 . . . . . . . .
7 . . . . . . .
9 . . . . . . . .
A . . . . . . . . . . . .
C . . . . . . . . . .
D . . . . . . . . . . . .
|
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*6
1/2 NPT female, two electrical connections and a blind plug*6
M20 female, two electrical connections and a blind plug*6
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
|
Integral indicator
►
|
D . . . . . . .
E . . . . . . .
N . . . . . . . .
|
Digital indicator*7
Digital indicator with the range setting switch (push button)*8
None
|
Mounting bracket ►
|
B . . . .
D . . . .
J . . . .
K . . . .
M . . . . .....
N . . . . .
|
304 SST 2-inch pipe mounting, flat type (for horizontal piping)
304 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting, flat type (for horizontal piping)
316 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting (for bottom process connection type)
None
|
Optional Codes
|
/ Optional specification
|
The “►” marks indicate the most typical selection for each specification.
*1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*2: Only applicable for Wetted parts material code S.
*3: Not applicable for measurement span code F.
*4: Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less.
*5: Not applicable for electrical connection code 0, 5, 7 and 9.
*6: Material of a blind plug is aluminum alloy or 304 SST.
*7: Not applicable for output signal code G.
*8: Not applicable for output signal code F.
Table. Wetted Parts Materials for Yokogawa Pressure Transmitter EJX110A-FMS5G-919DN/KS26/D4/N4/M01/T13
Wetted parts material code
|
Cover flange and process connector
|
Capsule
|
Capsule gasket
|
Vent/Drain plug
|
S #
|
ASTM CF-8M *1
|
Hastelloy C-276 *2 (Diaphragm) F316L SST, 316L SST (Others)
|
Teflon-coated 316L SST
|
316 SST
|
H #
|
ASTM CF-8M *1
|
Hastelloy C-276 *2
|
PTFE Teflon
|
316 SST
|
M #
|
ASTM CF-8M *1
|
Monel
|
PTFE Teflon
|
316 SST
|
T
|
ASTM CF-8M *1
|
Tantalum
|
PTFE Teflon
|
316 SST
|
A #
|
Hastelloy C-276 equivalent *3
|
Hastelloy C-276 *2
|
PTFE Teflon
|
Hastelloy C-276 *2
|
D #
|
Hastelloy C-276 equivalent *3
|
Tantalum
|
PTFE Teflon
|
Hastelloy C-276 *2
|
B #
|
Monel equivalent *4
|
Monel
|
PTFE Teflon
|
Monel
|
*1: Cast version of 316 SST. Equivalent to SCS14A.
*2: Hastelloy C-276 or ASTM N10276.
*3: Indicated material is equivalent to ASTM CW-12MW.
*4: Indicated material is equivalent to ASTM M35-2.