Product Information

Yokogawa Duplexed Safety Control Unit SSC60D-S2541[Product print page]

Product Name: Yokogawa Duplexed Safety Control Unit SSC60D-S2541
Product Type: SSC60D-S2541
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Duplexed Safety Control Unit SSC60D-S2541, are intelligent parts of the safety control station. Yokogawa Duplexed Safety Control Unit SSC60D-S2541, for Vnet/IP, Rack Mountable Type.


 Detailed description

Yokogawa Duplexed Safety Control Unit SSC60D-S2541


HARDWARE SPECIFICATIONS

For the criteria for the installation environment, refer to “ProSafe-RS Safety Instrumented System Overview” (GS 32Q01B10-31E).

 

Processor

MIPS R5000 Processor


Main Memory Capacity

128 MB


Memory Protection at Power Failure

Application program is stored in non-volatile memories.

Processor Module Management Information is stored in the storage memories backed up by a non- rechargeable battery. 

The batterys recommended replacement cycle is three years when it is used under the average ambient temperature of 30 °C or less.


Temperature Adaptability

A fan unit is provided for high temperature use where the safety control units (SSC60S-F/SSC60D-S2541-F) ambient temperature exceeds 40 °C.

 

Communications Interface

Vnet/IP interface: Dual-redundant

ESB bus interface: Dual-redundant

 

Communication on Vnet/IP

Yokogawa Duplexed Safety Control Unit SSC60D-S2541

Communication speed:   100 Mbps, Full duplex

Connection:    UTP cable (CAT5e or higher), RJ45 connector

Interface:   100 Base-TX compliance

Max. distance: 100 m (distance between SSC60S/ SSC60D-S2541 and Layer 2 switch)


Connecting Safety Node Units

Up to 13 safety node units can be connected to a safety control unit using SEC402 ESB bus coupler module and adding CFS1350 Node Expansion Package.

Up to 9 safety node units can be connected to a safety control unit using SEC401 ESB bus coupler module.

For installation, ESB bus coupler modules (SEC402/ SEC401) should be mounted on 7-th and 8-th slots.

ESB bus can be extended by Optical ESB bus repeater modules.


Number of I/O Modules Mounted

Up to eight for each safety control unit

Up to 110 for each SCS (using SEC402 ESB bus coupler module and CFS1350 Node Expansion Package)

Up to 78 for each SCS (using SEC401 ESB bus coupler module)


Power Requirements

Specify suffix codes.

Voltage: 100 to 120 V AC, 50 or 60 Hz Voltage: 220 to 240 V AC, 50 or 60 Hz Voltage: 24 V DC


Power Consumption

Yokogawa Duplexed Safety Control Unit SSC60D-S2541

• SSC60S-S/SSC60D-S2541-S

100 to 120 V AC model: 200 VA

200 to 240 V AC model: 230 VA

24 V DC model: 5.5 A

• SSC60S-F/SSC60D-S2541-F

100 to 120 V AC model: 240 VA

200 to 240 V AC model: 290 VA

24 V DC model: 7.0 A

 

Weight

Approximately 7.9 kg (for SSC60S-S) 

Approximately 13.0 kg (for SSC60S-F) 

Approximately 8.5 kg (for SSC60D-S2541-S) 

Approximately 13.0 kg (for SSC60D-S2541-F)


Mounting

Rack mounting: SSC60S-S/SSC60D-S2541-S rack mounted with eight M5 screws

SSC60S-F/SSC60D-S2541-F rack mounted with twelve M5 screws

Insulating Bushing: Supplied as accessories


Connections

Power Supply: Connected with M4 screws. 

Grounding: Connected with M4 screws.


MODEL AND SUFFIX CODES

Duplexed Safety Control Unit

Yokogawa Duplexed Safety Control Unit SSC60D-S2541

 

 

Description

Model

SSC60D

Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type)

 

 

 

 

Suffix

Codes

-S

Standard Type (-20 to 40 °C) (with ISA Standard G3 )

-F

Wide range temperature (-20 to 70 °C) type (with Fan unit and ISA Standard G3)

2

Dual-redundant power supply

5

With no explosion protection

E

With explosion protection

1

100-120 V AC power supply

2

220-240 V AC power supply

4

24 V DC power supply

1

CFS1300 Safety Control Function License

Option

Code

 

/ATDOC

 

Explosion Protection Manual


Note: Install the 19-inch rack mountable type devices in a keyed metallic cabinet to conform to the safety standards, the EMC

conformity standards and the explosion protection standards.

For details, refer to ProSafe-RS Installation Guidance (TI 32S01J10-01E).

Note: Select the option code “/ATDOC” to follow the ATEX Directive for use in potentially explosive atmospheres.



STANDARD ACCESSORIES

Yokogawa Duplexed Safety Control Unit SSC60D-S2541

 

Accessory

Part number

 

Description

 

Quantity

 

Remark

 

Insulating bushing

 

 

S9049PM

SSC60S-S/ SSC60D-S2541-S

 

8

 

 

Accessories

SSC60S-F/ SSC60D-S2541-F

 

12


The safety control unit is supplied with the following accessories.