Product Information

Yokogawa Duplexed Field Control Unit AFV10D-S41201[Product print page]

Product Name: Yokogawa Duplexed Field Control Unit AFV10D-S41201
Product Type: AFV10D-S41201
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Duplexed Field Control Unit AFV10D-S41201, for Vnet/IP and FIO, Yokogawa Duplexed Field Control Unit AFV10D-S41201. Please contact us: tekrachel @ 163.com


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Duplexed Field Control Unit AFV10D-S41201

for Vnet/IP and FIO, with 19 inch rack mountable type

Hardware Specifications

Yokogawa Duplexed Field Control Unit AFV10D-S41201, for Vnet/IP and FIO, with 19 inch rack mountable type   


For the installation specifications and the environmental conditions common to the systems, refer to “Vnet/IP System Overview (Vnet/IP Edition)” (GS 33K01A10- 50E).

 

Processor

VR5432 (133 MHz)


No. of Node Units Connectable

Max. 14/FCU

The total number of ESB Bus Node Units and ER Bus Node Units that can be connected to FCU are 14 or less. (ESB Bus Node Units: 9 or less)

LFS1500 allows up to 3 nodes, and can be expanded to 14 if LFS1550 Application capacity Expansion Package (for AFV10 ) is added.

To connect a node unit to the FCU, a Node Unit Expansion License (Option code: /NDEL) is required for the node unit.

 

Module configuration

Power Supply Module (PW481 or PW482 or PW484):

Two modules in case of a dual-redundant configuration.

Processor Module (CP451): Two modules in case of a dual-redundant configuration.

I/O Modules(*1): Max. 8

*1: Non-standard components.

 

ESB Bus Node Units Connection

Yokogawa Duplexed Field Control Unit AFV10D-S41201

When connecting an ESB Bus Node Unit to FCU, install ESB Bus Coupler Module (EC401) on FCU. EC401 must be installed in slot 7 and slot 8. For the dual-redundant configuration of the processor modules, EC401 must be installed in both slot 7 and slot 8.

In case ESB Bus has a single configuration, EC401 must be installed in slot 7 and keep slot 8 empty.


 

Regulatory Compliance

Yokogawa Duplexed Field Control Unit AFV10D-S41201

For the detailed information of following standards, see “System Overview (Vnet/IP Edition)” (GS 33K01A10-50E).

Safety Standards

[CSA] (for 100-120 V AC power supply)

[CE Marking] (for 220-240 V AC power supply)

EMC Conformity Standards

[CE Marking] (for 220-240 V AC and 24 V DC power supply)

[C-Tick Marking] (for 220-240 V AC and 24 V DC power supply)

[KC Marking] (for 220-240 V AC and 24 V DC power supply)

Standards for Hazardous Location Equipment

[FM Non-Incendive] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

[Type n] (for 24 V DC power supply)


Models and Suffix Codes

Duplexed Field Control Unit

Yokogawa Duplexed Field Control Unit AFV10D-S41201

 

 

Description

Model

AFV10D

Duplexed Field Control Unit (for Vnet/IP and FIO, for 19-inch Rack Mountable)

 

 

 

 

 

Suffix

Codes

-S

Standard type

4

Dual-Redundant Vnet/IP, Dual-Redundant power supply

1

Always 1

1

100–120 V AC power supply

2

220–240 V AC power supply

4

24 V DC power supply

5

Basic type with no explosion protection

6

With ISA Standard G3 option and no explosion protection

E

Basic type with explosion protection

F

With ISA Standard G3 option and explosion protection

1

LFS1500 Control Function for Field Control Station (for Vnet/IP and FIO)

Option

Code

 

/ATDOC

 

Explosion Protection Manual (*1)