Product Information

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC[Product print page]

Product Name: Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC
Product Type: AFV10D-S41151/ATDOC
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC, for Vnet/IP and FIO, Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC. Please contact us: tekrachel @ 163.com


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC

for Vnet/IP and FIO, with 19 inch rack mountable type

Hardware Specifications

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC, for Vnet/IP and FIO, with 19 inch rack mountable type  

For the installation specifications and the environmental conditions common to the systems, refer to “Vnet/IP System Overview (Vnet/IP Edition)” (GS 33K01A10- 50E).

 

Processor

VR5432 (133 MHz)

 

Main Memory Capacity

32 Mbyte

 

Memory Protection During Power Failure

Battery

Battery Back-up for Main Memory: Max. 72 hours

Battery Recharge Time: Min. 48 hours

 

FCU Status Contact Output

2 terminals (NC, C)

Contact Points open during FCU failure

Contact Rating: 30 V DC, max. 0.3 A

 

Communication Interface

Vnet/IP Interface: Dual-redundant

 

No. of Node Units Connectable

Max. 14/FCU

The total number of ESB Bus Node Units and ER Bus Node Units that can be connected to FCU are 14 or less. (ESB Bus Node Units: 9 or less)

LFS1500 allows up to 3 nodes, and can be expanded to 14 if LFS1550 Application capacity Expansion Package (for AFV10 ) is added.

To connect a node unit to the FCU, a Node Unit Expansion License (Option code: /NDEL) is required for the node unit.

 

Module configuration

Power Supply Module (PW481 or PW482 or PW484):

Two modules in case of a dual-redundant configuration.

Processor Module (CP451): Two modules in case of a dual-redundant configuration.

I/O Modules(*1): Max. 8

*1: Non-standard components.

 

ESB Bus Node Units Connection

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC

When connecting an ESB Bus Node Unit to FCU, install ESB Bus Coupler Module (EC401) on FCU. EC401 must be installed in slot 7 and slot 8. For the dual-redundant configuration of the processor modules, EC401 must be installed in both slot 7 and slot 8.

In case ESB Bus has a single configuration, EC401 must be installed in slot 7 and keep slot 8 empty.

 

ER Bus Node Units Connection

When connecting an ER Bus Node Unit to FCU, install ER Bus Interface Master Module (EB401) on FCU.

To make single configuration, EB401 must be installed in an odd-number slot, and keep empty the right side of the installed EB401.

See “ER Bus Interface Master Module (for FIO)” (GS 33K50F40-50E) for further information.


Weight

Approx. 7 kg (AFV10S)

Approx. 8 kg (AFV10D)

 

Regulatory Compliance

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC

For the detailed information of following standards, see “System Overview (Vnet/IP Edition)” (GS 33K01A10-50E).

Safety Standards

[CSA] (for 100-120 V AC power supply)

[CE Marking] (for 220-240 V AC power supply)

EMC Conformity Standards

[CE Marking] (for 220-240 V AC and 24 V DC power supply)

[C-Tick Marking] (for 220-240 V AC and 24 V DC power supply)

[KC Marking] (for 220-240 V AC and 24 V DC power supply)

Standards for Hazardous Location Equipment

[FM Non-Incendive] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

[Type n] (for 24 V DC power supply)


Models and Suffix Codes

Duplexed Field Control Unit

Yokogawa Duplexed Field Control Unit AFV10D-S41151/ATDOC

 

 

Description

Model

AFV10D

Duplexed Field Control Unit (for Vnet/IP and FIO, for 19-inch Rack Mountable)

 

 

 

 

 

Suffix

Codes

-S

Standard type

4

Dual-Redundant Vnet/IP, Dual-Redundant power supply

1

Always 1

1

100–120 V AC power supply

2

220–240 V AC power supply

4

24 V DC power supply

5

Basic type with no explosion protection

6

With ISA Standard G3 option and no explosion protection

E

Basic type with explosion protection

F

With ISA Standard G3 option and explosion protection

1

LFS1500 Control Function for Field Control Station (for Vnet/IP and FIO)

Option

Code

 

/ATDOC

 

Explosion Protection Manual (*1)

Insulating Partition Kit

 

 

Description

Part No.

T9083ND

Insulating Partition Kit


Configuration of Insulating Partition Kit

 

 

Description

 

Part No.

T9083NE

Insulating Partition

T9083NG

Insulating Partition for V net

Y9306LB

2 screws for T9083NG