Product Information

Yokogawa Node Unit ANR10D-426[Product print page]

Product Name: Yokogawa Node Unit ANR10D-426
Product Type: ANR10D-426
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Node Unit ANR10D-426, Yokogawa Node Unit ANR10D-426 for ER Bus. Yokogawa Centum VP, Yokogawa DCS. Favorable Price, Fastest Delivery. Please contact us: tekrachel @ 163.com


 Detailed description

Yokogawa Node Unit ANR10D-426

The ER Bus Node Unit has an interface function that communicates the analog I/O signals and contact I/O signals of a field with a Field Control Unit (FCU), as well as a function that supplies power to the I/O Modules.  

 

Hardware specifications for Yokogawa Node Unit ANR10D-426

No. of Node Units Connectable

Vnet/IP

Field Control Unit

Database

ESB Bus Node Units (ANB10 ) Connected per FCU

ER Bus Node Units (ANR10 )Connected per FCU

Total Number of ESB Bus Node Units ( ANB10 ) and ER Bus Node Units (ANR10 )Connected per FCU

AFV10

Control Function for Field Control Station (LFS1500)

Max. 3

Max. 3

Max. 3

Control Function for Field Control Station (LFS1500) plus Application Capacity Expansion Package (LFS1550)

Max. 9

Max. 14

Max. 14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vnet

Field Control Unit

Database

ESB Bus Node Units (ANB10 ) Connected per FCU

ER Bus Node Units (ANR10 )Connected per FCU

Total Number of ESB Bus Node Units ( ANB10 ) and ER Bus Node Units (ANR10 ) Connected per FCU

AFF50

Control Function for Compact Field Control Station (LFS1350)

Max. 3

Max. 3

Max. 3

AFG30

AFG40

Control Function for Enhance Field Control Station (LFS1330) with Node expanded databases

Max. 10

Max. 14

Max. 15

Others

Max. 10 (*1)

Max. 9 (*1)

Max. 10 (*1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: In Case of AFG81 and AFG82 ,there are total number with SIO Nest (for CENTUM V or CENTUM-XL).

Total number of SIO: Max 5/FCU

 

Remote Node Connection

Yokogawa Node Unit ANR10D-426

ER Bus: Max.4/FCU

When connecting a ER Bus Node Unit to a ESB Bus Node Unit or Field Control Unit, install ER Bus Interface Master Module (EB401) to the ESB Bus Node Unit or Field Control Unit.

To make single configuration, EB401 must be installed in an odd-number slot, and make a space on the right side of the installed EB401.

See “ER Bus Interface Master Module (for FIO)” (GS 33K50F40-50E) for further information.

 

Power Supply

Specify with Suffix Codes

Voltage: 100-120 V AC, Frequency: 50/60 Hz

Voltage: 220-240 V AC, Frequency: 50/60 Hz

Voltage: 24 V DC

 

Electric Power Consumption

100-120 V AC: 200 VA, 120 W

220-240 V AC: 230 VA, 120 W

24 V DC: 5.5 A

 

Weight for Yokogawa Node Unit ANR10D-426

10 kg (including 8 I/O Modules)

 

Mounting

19-inch Rack Mounting

             Rack mount (M5 x 4 screws)

             Insulation bash (accessory)

 

Regulatory Compliance for Yokogawa Node Unit ANR10D-426

For the detailed information of following standards, see System Overview (GS 33K01A10-50E).

Safety Standards

     [CSA]                    (for 100-120 V AC and 24 V DC power supply)

     [CE Marking]        (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

EMC Conformity Standards

    [CE Marking]          (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

    [C-Tick Marking]    (for 220-240 V AC and 24 V DC power supply)

    [KC Marking]         (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

Standards for Hazardous Location Equipment

     [CSA Non-Incendive]    (for 100-120 V AC and 24 V DC power supply)

     [FM Non-Incendive]      (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

     [Type n]                        (for 24 V DC power supply