Product Information

Yokogawa Analog Output Module AAI543-H00[Product print page]

Product Name: Yokogawa Analog Output Module AAI543-H00
Product Type: AAI543-H00
Exhibitors: CHINO
Product Documentation: No Related Documents

Brief

Yokogawa Analog Output Module AAI543-H00 4 to 20 mA, 16-channel, Isolated, standard or fast switch-over response in redundant configuration Yokogawa Analog Output Module AAI543-H00


 Detailed description

Yokogawa Analog Output Module AAI543-H00


Current Output Module (Isolated)

Yokogawa Analog Output Module AAI543-H00 provides 16 outputs of 4 – 20 mA signal. Yokogawa Analog Output Module AAI543-H00 can be used in dual-redundant configuration. (*1)

Items

Specifications

Model

AAI543-£5£/-£E£

AAI543-£6£/-£F£ (*2)

 

Number of output channels

16, isolated, standard switch-over

response in redundant configuration (*3)

16, isolated, fast switch-over response in

redundant configuration (*3)

Output signal

4 to 20 mA

Withstanding voltage

Between output and system: 1500 V AC, for 1 minute (*4)

Allowable load resistance

0 to 750

Circuit-open detection

Less than 0.65 mA

Accuracy

±48 µA

Data update period

10 ms

Drift due to ambient temperature change

±16 µA/10 ˚C

Maximum current consumption

230 mA (5 V DC), 540 mA (24 V DC)

Weight

Approx. 0.40 kg

External communication

Pressure clamp terminal, MIL connector cable, dedicated cable (KS1)

HART communication

Available

 

*1:      A dual-redundant configuration is enabled by using two identical modules with the same suffix codes.

*2:      When Yokogawa Analog Output Module AAI543-H00 is installed in a node unit that conforms to the temperature environment, use it in the ambient temperature within 0 to 60 ºC range.

*3:      When a switch over from control to stand-by module takes place in the dual-redundant configuration, the maximum period of time when the field output falls below 4 mA is 100 ms for Yokogawa Analog Output Module AAI543-H00 (standard switch-over response) and 2 ms for AAI543-£6£/-£F£ (fast switch-over response). In case of connecting fast response type field devices, use AAI543-

£6£/-£F£ (fast switch-over response) in the dual-redundant configuration. 

*4:      When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When

the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.


MODEL AND SUFFIX CODES

Yokogawa Analog Output Module AAI543-H00

 

 

Description

Model

AAI543

Analog Output Module (4 to 20 mA, 16-channel, Isolated)

 

 

 

 

Suffix

Codes

-S

Standard type

-H

With digital communication (HART protocol)

5

Standard switch-over response in redundant configuration with no explosion protection(*1)

6

Fast switch-over response in redundant configuration with no explosion protection(*2)

E

Standard switch-over response in redundant configuration with explosion protection(*1)

F

Fast switch-over response in redundant configuration with explosion protection(*2)

0

Basic type

1

With ISA Standard G3 option

3

With ISA Standard G3 option and temperature (-20 to 70 °C) option

 

 

 

Option

Codes

/K4A00

With KS Cable Interface Adapter (For connecting AEA4D Terminal Board) [Model: ATK4A-00]

/A4S00

With Pressure Clamp Terminal Block [Model: ATA4S-00]

/A4S10

With Pressure Clamp Terminal Block (surge absorber) [Model: ATA4S-10]

/A4D00

With Dual Pressure Clamp Terminal Block [Model: ATA4D-00]

/A4D10

With Dual Pressure Clamp Terminal Block (surge absorber) [Model: ATA4D-10]

/CCC01

With Connector Cover for MIL Cable [Model: ACCC01]

 

*1:      If “standard switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option and temperature (-20 to 70 °C) option” may be specified.

*2:      If “fast switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option” may be specified.