Product Information

Yokogawa Conductivity Sensor SC8SG[Product print page]

Product Name: Yokogawa Conductivity Sensor SC8SG
Product Type: SC8SG
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Conductivity Sensor SC8SG Yokogawa Conductivity Sensor SC8SG Flow-through Type, 2-electrode system or 4-electrode system


 Detailed description

Yokogawa Conductivity Sensor SC8SG


General Specifications: 

Cable with pin terminals (applicable to FLXA21,SC202G and SC202SJ)

Cable with M3 ring terminals (applicable to SC450G,)

Cable with fork terminals (applicable to SC202G and SC202/TB)

Cable with M4 ring terminals (applicable to FLXA21)

Object of measurement: Conductivity of liquids

Measuring Principle:  2-electrode system or 4-electrode system

Cell Constants:  0.01 cm-1   or 10 cm-1 (for two-electrode system)

                              10 cm-1   (for four-electrode system)

Temperature Range: 0˚ to 100˚C (130˚C maximum only for 0.01 cm-1   cell constant detectors, excluding those with polypropylene chambers)

Pressure:  1000 kPa max. (500 kPa maxi- mum for detectors with polypropy- lene chambers)

Flow rate of Sample Solution: No particular limitation applies, although a value of less than 20 l/ min. is recommended for flow- through detectors.


(Note) No limitation appliesto flow rate (flow velocity) as far as measurement is concerned. Take care, however, when usingflow-through detectors. Electrodes or the inner wallsof a liquid chamber may wear put drastically at higher flow speeds if a measured solution contains slurry. Air bubblesshould not be mixedin the sample solutions to obtain correct measured values.


RTD for Temperature Compensation:

Yokogawa Conductivity Sensor SC8SG

Pt1000 (built into the sensor) Construction : Rainproof encapsulation (compatible with the JIS C0920 Japanese Industrial Standard)


Weight: 

Yokogawa Conductivity Sensor SC8SG

Screw-in type: approximately 1.3 kg (excluding the cable)

Flow-through type (SCS14 chamber): approximately 3.1 kg (excluding the cable)

Flow-through type (SCS14 chamber, flanged): approximately 4.5 kg (excluding the cable)

Flow-through type (polypropylene chamber): approximately 2.7 kg (excluding the cable)

Flow-through type (polypropylene chamber, flanged): approximately 3.2 kg (excluding the cable)

Cable: 0.3 kg for 5.5-m length; 0.5 kg for 10-m length; 0.9 kg for 20-m length.


Process Connection: Screw-in or flow-through


Construction of Wetted Part:

Yokogawa Conductivity Sensor SC8SG

• Sensor-holding base:

SUS316 and fluoro-rubber when using screw- in type holder or the chamber made of stainless steel. PP and fluoro-rubber when using the chamber made of PP.

• 0.01 cm-1 cell constant, two-electrode sensor:

SUS316 and ethylene chloride trifluoride

• 10 cm-1   cell constant, two-electrode sensor:

reinforced epoxy resin and graphite

• 10 cm-1   cell constant, four-electrode sensor:

polyvinylidene difluoride, glass and platinum

• Stem (flow-through type):

SCS14 or polypropylene resin


Installation:

Yokogawa Conductivity Sensor SC8SG

• Screw-in type—held by the process piping

• Flow-through type (polypropylene chamber)

—mounted on a pipe (nominal diameter of 50 mm  2 in.)

• Flow-through type (SCS14 chamber)

—held by the process piping



Spare Parts for SC8SG

Yokogawa Conductivity Sensor SC8SG

Parts No.

Description

K9208BA


K9208BC


K9208BD

K9208BK G9303EB

0.01cm-1 cell constant, two-electrode sensor

10cm-1 cell constant, two-electrode sensor

10cm-1 cell constant, four-electrode sensor

Welding socket for screw-in model

O-ring