Yokogawa Diaphragm Sealed Differential Pressure Transmitter EJA118N-EMSA26EA-AB05-97DB03-92EB/E1
Measurement Types Primary Variable Differential Pressure (DP) Reference Accuracy Primary Variable ±0.2% of DP Span Rangeability Primary Variable M-Capsule: 40:1 H-Capsule: 20:1
STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for
PROFIBUS PA communication type marked with “0.”
Measurement Ranges:
Capsule
Measurement Span
Measurement Range
M
2.5 to 100 kPa
{250 to 10000 mmH2O}
-100 to 100 kPa
{-10000 to 10000 mmH2O}
H
25 to 500 kPa
{0.25 to 5 kgf/cm2}
-500 to 500 kPa
{-5 to 5 kgf/cm2}
Accuracy: See Table 2-1, 2-2 and 2-3. Ambient Temperature Limits: -40 to 60 oC (-40 to 140 oF) (general-use type) -30 to 60 oC (-22 to 140 oF) (with integral indicator) (Note : The ambient temperature limits must be within the fill fluid operating temperature range, see table 1.) (See ‘Optional Specifications’ for Explosion-protected types) Ambient Temperature Effect: See Table 2-1, 2-2 and 2-3. Process Temperature Limits: See Table 1. (See ‘Optional Specifications’ for Explosion-protected types) Ambient Humidity Limits: 5 to 100 % R.H.(at 40 oC) Working Pressure Range: 2.7 kPa abs{20 mmHg abs} to flange rating pressure. For atmospheric pressure or below, see Figure 2. Static Pressure Effect: See Table 2-1, 2-2 and 2-3. Power Supply Effect “0”: ::!0.005 %/V(21.6 to 32 V DC, 350 D) Mounting: Transmitter; 2-inch pipe mounting Diaphragm seals; flange mounting Mounting Flange Rating: See ‘Model and Suffix Codes.’ Flanges conforming to ANSI are serrated on their gasket surfaces (ANSI B16.5). Note: For model EJA118W-FMHJ2DA-CA06-9AEB wetted parts material code H, T, or U, no serration is worked. Degrees of Protection: IP67, NEMA4X Explosion-protected Construction: See ‘Optional Specifications.’ Electrical Connection: See ‘Model and Suffix Codes.’
Ordering Information
Specify the following when ordering 1. Model, suffix codes, and optional codes 2. Calibration range and units: 1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -32000 to 32000. 2) Specify only one unit from the table, ‘Settings when shipped.’ 3. Select linear or square root for output mode and display mode. Note: If not specified, the instrument is shipped set for linear mode. 4. Select normal or reverse for operation mode Note: If not specified, the instrument is shipped in normal operation mode. 5. Display scale and units (for transmitters equipped with integral indicator only) Specify either 0 to 100 % or engineering unit scale and ‘Range and Unit’ for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -19999 to 19999. 6. Tag Number (if required) 7. Process fluid temperature for zero compensation (if required)