Rosemount Pressure Transmitter 2051CD2A22A1AB4M5, Rosemount Coplanar™ platform enables integration of primary elements, manifolds, and remote seal. Rosemount Pressure Transmitter 2051CD2A22A1AB4M5, Best in C


 Detailed description

Rosemount Pressure Transmitter 2051CD2A22A1AB4M5


Features and Benefits

Rosemount Pressure Transmitter 2051CD2A22A1AB4M5

Local Operator Interface

Our Local Operator Interface features straightforward menus and built in configuration buttons, allowing you to commission the device on the spot without complicated training or tools – even in hazardous area locations. 
             Request a Quote – Add option code M4

Integrated Wireless
Quickly deploy new monitoring points to access remote and hard to reach locations that were previously untapped by using the Rosemount 2051 Wireless Pressure Products.

 


Communication Protocols
Emerson offers a full suite of protocols including: 4–20mA HART (Revision 5 and 7), WirelessHART, FOUNDATION™ Fieldbus, and Profibus PA with the latest DD or DTM so you can have seamless integration with any host.


Specifications

Rosemount Pressure Transmitter 2051CD2A22A1AB4M5

Measurement Types

Differential, Gauge, Absolute, Level and Flow

Output

4-20mA HART®, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power Wireless™, WirelessHART™

Safety Certified

SIL 2/3 certified to IEC 61508

Reference Accuracy

± 0.065% of span 
± 0.05% of span (with high accuracy option P8)

Long Term Stability

0.1% of URL for 2 years 
± 0.125% of URL for 5 years (with high accuracy option P8)

Rangedown

100:1

 

Functional specifications 

Rosemount Pressure Transmitter 2051CD2A22A1AB4M5

Range and sensor limits

Table 7. Range and Sensor Limits

 

2051CD, 2051CF, 2051CG, 2051L

Range

 

 

 

Minimum span

Range and sensor limits

 

 

Upper (URL)

Lower (LRL)

2051C Differential

2051CF Flowmeters

 

2051C Gage(1)

 

2051L Differential

 

2051L Gage(1)

1

0.5 inH2O

(1.2 mbar)

25 inH2O

(62.3 mbar)

25 inH2O

(62.1 mbar)

25 inH2O

(–62.1 mbar)

N/A

N/A

2

2.5 inH2O

(6.2 mbar)

250 inH2O

(0.62 bar)

250 inH2O

(0.62 bar)

250 inH2O

(–0.62 bar)

250 inH2O

(–0.62 bar)

250 inH2O

(0.62 bar)

3

10 inH2O

(24.9 mbar)

1000 inH2O

(2.49 bar)

-1000 inH2O

(-2.49 bar)

393 inH2O

(–979 mbar)

1000 inH2O

(–2.49 bar)

393 inH2O

(979 mbar)

4

3 psi

(0.207 bar)

300 psi

(20.7 bar)

-300 psi

(-20,7 bar)

14.2 psig

(–979 mbar)

300 psi

(–20.7 bar)

14.2 psig

(979 mbar)

5

20 psi

(1.38 bar)

2000 psi

(137.9 bar)

-2000 psi

(-137.9 bar)

14.2 psig

(–979 mbar)

N/A

N/A

 (1)  Assumes atmospheric pressure of 14.7 psig.


 Table 8. Range and Sensor Limits

Range

2051T

 

Minimum span

Range and sensor limits

Upper

(URL)

Lower

(LRL) (Abs)

Lower(1)

(LRL) (Gage)

1

0.3 psi (20.7 mbar)

30 psi (2.07 bar)

0 psia (0 bar)

14.7 psig (1.01 bar)

2

1.5 psi (0.103 bar)

150 psi (10.3 bar)

0 psia (0 bar)

14.7 psig (1.01 bar)

3

8 psi (0.55 bar)

800 psi (55.2 bar)

0 psia (0 bar)

14.7 psig (1.01 bar)

4

40 psi (2.76 bar)

4000 psi (275.8 bar)

0 psia (0 bar)

14.7 psig (1.01 bar)

5

2,000 psi (137.9 bar)

10,000 psi (689.5 bar)

0 psia (0 bar)

14.7 psig (1.01 bar)

 (1)  Assumes atmospheric pressure of 14.7 psig.

 

  Service

Liquid, gas, and vapor applications

Protocols 

4–20 mA HART (Output Code A)

Power supply

External power supply required. Standard transmitter operates on 10.5 to 42.4 Vdc with no load.

Load limitations


Maximum loop resistance is determined by the voltage level of the external power supply, as described  by:

Max. Loop Resistance = 43.5 (Power Supply Voltage - 10.5)


Indication

Optional two line LCD/LOI Display


Zero and span adjustment requirements

Zero and span values can be set anywhere within the range limits stated in Table 7 and Table 8.

Span must be greater than or equal to the minimum span stated in Table 7 and Table 8.

 

Output

Two-wire 4-20mA, user selectable for linear or square root output. Digital process variable superimposed on 4-20 mA signal, available to any host that conforms to HART protocol.

 

2051

Digital communications based on HART Revision 5 protocol.

 

2051 with selectable HART

The 2051 with Selectable HART comes with Selectable HART Revisions. Digital communications based on HART Revision 5 (default) or Revision 7 (option code HR7) protocol can be selected. The HART revision can be switched in the field using any HART based configuration tool or the optional local operator interface (LOI).

 

Local operator interface

The LOI utilizes a 2 button menu with internal and external configuration buttons. Internal buttons are always configured for Local Operator Interface. External Buttons can be configured for either LOI, (option code M4), Analog Zero and Span (option code D4) or Digital Zero Trim (option code DZ). See 2051 with Selectable HART product manual (00809-0100-4107) for LOI configuration menu.


Rosemount Pressure Transmitter 2051CD2A22A1AB4M5

Rosemount Coplanar Pressure Transmitter 2051C 
Rosemount In-Line Pressure Transmitter 2051T 
Rosemount Flowmeters 2051CF 
Rosemount Liquid Level Transmitter 2051L