Rosemount Pressure Transmitter 2051
Features and Benefits Rosemount Pressure Transmitter 2051 Local Operator Interface Our Local Operator Interface features straightforward menus and built in configuration buttons, allowing you to commission the device on the spot without complicated training or tools – even in hazardous area locations. Request a Quote – Add option code M4 Integrated Wireless Quickly deploy new monitoring points to access remote and hard to reach locations that were previously untapped by using the Rosemount 2051 Wireless Pressure Products. Communication Protocols Emerson offers a full suite of protocols including: 4–20mA HART (Revision 5 and 7), WirelessHART, FOUNDATION™ Fieldbus, and Profibus PA with the latest DD or DTM so you can have seamless integration with any host.
Features and Benefits
Local Operator Interface
Our Local Operator Interface features straightforward menus and built in configuration buttons, allowing you to commission the device on the spot without complicated training or tools – even in hazardous area locations. Request a Quote – Add option code M4
Integrated Wireless Quickly deploy new monitoring points to access remote and hard to reach locations that were previously untapped by using the Rosemount 2051 Wireless Pressure Products.
Communication Protocols Emerson offers a full suite of protocols including: 4–20mA HART (Revision 5 and 7), WirelessHART, FOUNDATION™ Fieldbus, and Profibus PA with the latest DD or DTM so you can have seamless integration with any host.
Specifications
Measurement Types
Differential, Gauge, Absolute, Level and Flow
Output
4-20mA HART®, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power Wireless™, WirelessHART™
Safety Certified
SIL 2/3 certified to IEC 61508
Reference Accuracy
± 0.065% of span ± 0.05% of span (with high accuracy option P8)
Long Term Stability
0.1% of URL for 2 years ± 0.125% of URL for 5 years (with high accuracy option P8)
Rangedown
100:1
Functional specifications
Range and sensor limits
Table 7. Range and Sensor Limits
2051CD, 2051CF, 2051CG, 2051L Range Minimum span Range and sensor limits Upper (URL) Lower (LRL) 2051C Differential 2051CF Flowmeters 2051C Gage(1) 2051L Differential 2051L Gage(1) 1 0.5 inH2O (1.2 mbar) 25 inH2O (62.3 mbar) –25 inH2O (–62.1 mbar) –25 inH2O (–62.1 mbar) N/A N/A 2 2.5 inH2O (6.2 mbar) 250 inH2O (0.62 bar) –250 inH2O (–0.62 bar) –250 inH2O (–0.62 bar) –250 inH2O (–0.62 bar) –250 inH2O (–0.62 bar) 3 10 inH2O (24.9 mbar) 1000 inH2O (2.49 bar) -1000 inH2O (-2.49 bar) –393 inH2O (–979 mbar) –1000 inH2O (–2.49 bar) –393 inH2O (–979 mbar) 4 3 psi (0.207 bar) 300 psi (20.7 bar) -300 psi (-20,7 bar) –14.2 psig (–979 mbar) –300 psi (–20.7 bar) –14.2 psig (–979 mbar) 5 20 psi (1.38 bar) 2000 psi (137.9 bar) -2000 psi (-137.9 bar) –14.2 psig (–979 mbar) N/A N/A (1) Assumes atmospheric pressure of 14.7 psig. Table 8. Range and Sensor Limits Range 2051T Minimum span Range and sensor limits Upper (URL) Lower (LRL) (Abs) Lower(1) (LRL) (Gage) 1 0.3 psi (20.7 mbar) 30 psi (2.07 bar) 0 psia (0 bar) –14.7 psig (–1.01 bar) 2 1.5 psi (0.103 bar) 150 psi (10.3 bar) 0 psia (0 bar) –14.7 psig (–1.01 bar) 3 8 psi (0.55 bar) 800 psi (55.2 bar) 0 psia (0 bar) –14.7 psig (–1.01 bar) 4 40 psi (2.76 bar) 4000 psi (275.8 bar) 0 psia (0 bar) –14.7 psig (–1.01 bar) 5 2,000 psi (137.9 bar) 10,000 psi (689.5 bar) 0 psia (0 bar) –14.7 psig (–1.01 bar) (1) Assumes atmospheric pressure of 14.7 psig. Service Liquid, gas, and vapor applications Protocols 4–20 mA HART (Output Code A) Power supply External power supply required. Standard transmitter operates on 10.5 to 42.4 Vdc with no load. Load limitations
2051CD, 2051CF, 2051CG, 2051L
Range
Minimum span
Upper (URL)
Lower (LRL)
2051C Differential
2051CF Flowmeters
2051C Gage(1)
2051L Differential
2051L Gage(1)
1
0.5 inH2O
(1.2 mbar)
25 inH2O
(62.3 mbar)
–25 inH2O
(–62.1 mbar)
N/A
2
2.5 inH2O
(6.2 mbar)
250 inH2O
(0.62 bar)
–250 inH2O
(–0.62 bar)
3
10 inH2O
(24.9 mbar)
1000 inH2O
(2.49 bar)
-1000 inH2O
(-2.49 bar)
–393 inH2O
(–979 mbar)
–1000 inH2O
(–2.49 bar)
4
3 psi
(0.207 bar)
300 psi
(20.7 bar)
-300 psi
(-20,7 bar)
–14.2 psig
–300 psi
(–20.7 bar)
5
20 psi
(1.38 bar)
2000 psi
(137.9 bar)
-2000 psi
(-137.9 bar)
(1) Assumes atmospheric pressure of 14.7 psig.
Table 8. Range and Sensor Limits
2051T
Upper
(URL)
Lower
(LRL) (Abs)
Lower(1)
(LRL) (Gage)
0.3 psi (20.7 mbar)
30 psi (2.07 bar)
0 psia (0 bar)
–14.7 psig (–1.01 bar)
1.5 psi (0.103 bar)
150 psi (10.3 bar)
8 psi (0.55 bar)
800 psi (55.2 bar)
40 psi (2.76 bar)
4000 psi (275.8 bar)
2,000 psi (137.9 bar)
10,000 psi (689.5 bar)
Service
Liquid, gas, and vapor applications
Protocols
4–20 mA HART (Output Code A)
Power supply
External power supply required. Standard transmitter operates on 10.5 to 42.4 Vdc with no load.
Load limitations
Maximum loop resistance is determined by the voltage level of the external power supply, as described by:
Max. Loop Resistance = 43.5 (Power Supply Voltage - 10.5)
Indication Optional two line LCD/LOI Display Zero and span adjustment requirements Zero and span values can be set anywhere within the range limits stated in Table 7 and Table 8. Span must be greater than or equal to the minimum span stated in Table 7 and Table 8. Output Two-wire 4-20mA, user selectable for linear or square root output. Digital process variable superimposed on 4-20 mA signal, available to any host that conforms to HART protocol. 2051 Digital communications based on HART Revision 5 protocol. 2051 with selectable HART The 2051 with Selectable HART comes with Selectable HART Revisions. Digital communications based on HART Revision 5 (default) or Revision 7 (option code HR7) protocol can be selected. The HART revision can be switched in the field using any HART based configuration tool or the optional local operator interface (LOI). Local operator interface The LOI utilizes a 2 button menu with internal and external configuration buttons. Internal buttons are always configured for Local Operator Interface. External Buttons can be configured for either LOI, (option code M4), Analog Zero and Span (option code D4) or Digital Zero Trim (option code DZ). See 2051 with Selectable HART product manual (00809-0100-4107) for LOI configuration menu.
Indication
Optional two line LCD/LOI Display
Zero and span adjustment requirements
Zero and span values can be set anywhere within the range limits stated in Table 7 and Table 8.
Span must be greater than or equal to the minimum span stated in Table 7 and Table 8.
Two-wire 4-20mA, user selectable for linear or square root output. Digital process variable superimposed on 4-20 mA signal, available to any host that conforms to HART protocol.
2051
Digital communications based on HART Revision 5 protocol.
2051 with selectable HART
The 2051 with Selectable HART comes with Selectable HART Revisions. Digital communications based on HART Revision 5 (default) or Revision 7 (option code HR7) protocol can be selected. The HART revision can be switched in the field using any HART based configuration tool or the optional local operator interface (LOI).
Local operator interface
Rosemount Pressure Transmitter 2051:
Rosemount Coplanar Pressure Transmitter 2051C Rosemount In-Line Pressure Transmitter 2051T Rosemount Flowmeters 2051CF Rosemount Liquid Level Transmitter 2051L
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel tekrachel@163.com
Add.: Room 2401 Building D Greenland Central Plaza, Science City, Huangpu District, Guangzhou 510663, Guangdong Province, China.