Yokogawa I/O Expansion Cabinet ACB41-S2110
GENERAL
Yokogawa I/O Expansion Cabinet ACB41-S2110 The I/O Expansion Cabinet is used to install a Node Unit (NU) and Compact Field Control Unit (for FIO). It can be mounted beside a field control unit (FCU) or separately. A Node Unit and Compact Field Control Unit (for FIO) can be installed at the front and rear of the cabinet.
HARDWARE SPECIFICATIONS
Yokogawa I/O Expansion Cabinet ACB41-S2110 For the installation specifications and environmental conditions that are common to the systems, refer to “System Overview (GS 33K01A20-50E).” Installable NU Type Node Unit: Rack mountable type Duplexed Node Unit: Rack mountable type Compact Field Control Unit (for FIO): AFF50S Compact Duplexed Field Control Unit (for FIO): AFF50D Max. No. of Installable NU The installation patterns shown below are selectable. Max. 4 AFF50 (Front side: 2, Rear end: 2) 1 AFF50 + Max.3 Node Unit (Front side) Max. 8 Node Unit (Front side: 4, Rear end: 4) Fan Alarm Contact Output Three terminals (NC, NO, C) Contact Rating: Rated voltage: 30 V DC Rated current: Max. 0.3 A Power Supply (specify with Suffix Codes) Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Power Consumption 100-120 V AC: 1700 VA (at max. node installation) 220-240 V AC: 1900 VA (at max. node installation) 24 V DC: 46 A (at max. node installation) Connection Power Supply: M6 screw terminal connection (Dual power supply is also possible) Grounding: M8 bolt terminal connection Weight Approx. 400 kg (at max. installation)
MODELS AND SUFFIX CODES I/O Expansion Cabinet
Description
Model
ACB41
I/O Expansion Cabinet (for FIO)
Suffix
Codes
-S
Standard Type
1
Front/Rear: For Node Unit Mounting
2
Front: For Node Unit Mounting
Rear: For 19-inch Rack Equipment Mounting
3
Front: For 19-inch Rack Equipment Mounting (*3) Rear: For 19-inch Rack Equipment Mounting
0
No Power Supply (Applies only to -S3) (*3)
Single Power System
Dual Power System
100-120 V AC Power Supply
220-240 V AC Power Supply
4
24 V DC Power Supply
Always 0
Option
/£-5S3
Field Control Unit [Model/Suffix Code : AFF50S-H3££01] Single Power System and Dual-Redundant V net
/£-5S4
Field Control Unit [Model/Suffix Code : AFF50S-H4££01] Dual-Redundant Power System and Dual-Redundant V net
/£-5D4
Duplexed Field Control Unit [Model/Suffix Code : AFF50D-H4££01] Dual-Redundant Power System and Dual-Redundant V net
/£-S1L
Node Unit for Single ESB Bus and Single Power Supply [Model/Suffix Code: ANB10S-3£5/NDEL] (*4)
/£-S2L
Node Unit for Single ESB Bus and Dual-Redundant Power Supply
[Model/Suffix Code: ANB10S-4£5/NDEL] (*4)
/£-D2L
Node Unit for Dual-Redundant ESB Bus and Dual-Redundant Power Supply
[Model/Suffix Code: ANB10D-4£5/NDEL] (*4)
/££-S81
Node Unit for Single ESB Bus and Single Power System (*2)
/££-S82
Node Unit for Single ESB Bus and Dual-Redundant Power System (*2)
/££-D82
Node Unit for Dual-Redundant ESB Bus and Dual-Redundant power supply (*2)
/££-R81
Node Unit for Single ER Bus and Single power supply (*2)
/££-R82
Node Unit for Single ER Bus and Dual-Redundant power supply (*2)
/££-B82
Node Unit for Dual-Redundant ER Bus and Dual-Redundant power supply (*2)
/CH
Channel Base with cable hole (*1)
/CE
With CE Marking, C-Tick Marking and KC Marking
/ATDOC
Explosion Protection Manual (*5)
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel
Add.: Room 2401 Building D Greenland Central Plaza, Science City, Huangpu District, Guangzhou 510663, Guangdong Province, China.