Product Information

Yokogawa Pressure Transmitter EJX120A-DE5J-710DB[Product print page]

Product Name: Yokogawa Pressure Transmitter EJX120A-DE5J-710DB
Product Type: EJX120A-DE5J-710DB
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Pressure Transmitter EJX120A-DE5J-710DB measure liquid, gas or steam flow as well as liquid level, density and pressure. Yokogawa Pressure Transmitter EJX120A-DE5J-710DB


 Detailed description

Manufacturer: Yokogawa Electric Corporation

Yokogawa Pressure Transmitter EJX120A-DE5J-710DB

The high performance draft range EJX120A features single crystal silicon resonant sensor and is suitable to measure liquid,gas, or steam flow as well as liquid level, density and pressure. EJX120A-DE5J-710DB outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.Other key features include quick response, remoteset-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi- sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement. Yokogawa Pressure Transmitter EJX120A-DE5J-710DB

STANDARD SPECIFICATIONS 

Refer to GS 01C25T02-01EN for Fieldbus communication type and GS 01C25T04-01EN for PROFIBUS PA communication type for the items marked with “◊.”

SPAN AND RANGE LIMITS  Yokogawa Pressure Transmitter EJX120A-DE5J-710DB

Measurement

Span/Range

kPa

inH2O (/D1)

mbar

(/D3)

mmH2O (/D4)

E

Span

0.025 to 1 (0.1 to 1)

0.1 to 4 (0.4 to 4)

0.25 to 10 (1 to 10)

2.5 to 100 (10 to 100)

Range

-1 to 1

-4 to 4

-10 to 10

-100 to 100

PERFORMANCE SPECIFICATIONS Yokogawa Pressure Transmitter EJX120A-DE5J-710DB

Zero-based calibrated span, linear output, wetted parts material code S and silicone oil, unless otherwise mentioned.

For Fieldbus and PROFIBUS PA communication types, use calibrated range instead of span in the following specifications.

Specification Conformance

EJX series ensures specification conformance to at least ±3σ.

Yokogawa Pressure Transmitter EJX120A-DE5J-710DB

Model and Suffix Codes

Model

Suffix Codes

Description

EJX120A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Differential pressure transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5 protocol)

4 to 20 mA DC with digital communication (HART 5 / HART 7 protocol) (Refer to GS 01C25T01-01EN)

Digital communication (FOUNDATION Fieldbus protocol, refer to

GS 01C25T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to GS 01C25T04-01EN)

Measurement span (capsule)

E . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0.025 to 1 kPa (0.1 to 4 inH2O)

Wetted parts material *1

¨ . . . . . . . . . . . . . . . . . . . . . . . .

Refer to Wetted Parts Material Table below.

Process connections

0 . . . . . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . . . . . .

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connecto

with Rc1/2 female process connecto

with 1/4 NPT female process connector with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts materia

J . . . . . . . . . . . . . .

G. . . . . . . . . . . . .

C . . . . . . . . . . . . . .

B7 carbon steel

316L SST

660 SST

Installation

-7 . . . . . . . . . . . .


-8 . . . . . . . . . . . .

-9 . . . . . . . . . . . .

-U . . . . . . . . . . . .

Vertical piping, left side high pressure, and proces connection downside

Horizontal piping and right side high pressur

Horizontal piping and left side high pressur

Universal flange

Amplifier housing

1 . . . . . . . . . .

3 . . . . . . . . . .

2 . . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties*2

ASTM CF-8M stainless steel*3

Electrical connection

0 . . . . . . . .

2 . . . . . . . .

4 . . . . . . . .

5 . . . . . . . .

7 . . . . . . . .

9 . . . . . . .

A . . . . . . . . . . .

C . . . . . . . . . . .

D . . . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blin plug

M20 female, two electrical connections without blind plugs

G1/2 female, two electrical connections and a blind plug*4

1/2 NPT female, two electrical connections and a blin plug*4

M20 female, two electrical connections and a blind plug*4

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

D . . . . . .

E . . . . . .

N . . . . . 

Digital indicator*5

Digital indicator with the range setting switch (push button)*6

None

Mounting bracket                                  

B . . . .

D . . . .

J . . . .

K . . . .

N . . . 

304 SST 2-inch pipe mounting, flat type (for horizonta piping)

304 SST 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting, flat type (for horizonta piping)

316 SST 2-inch pipe mounting, L type (for vertical piping) None

Optional Codes

¨/ Optional specification