Yokogawa Absolute Pressure Transmitters EJA530A-DAS7N-02DN/HAC/FF1
Overview:
Yokogawa Absolute Transmitters EJA530A-DAS7N-02DN/HAC/FF1 can be used to measure liquid, gas, or steam pressure. Yokogawa Absolute Pressure Transmitters EJA530A-DAS7N-02DN/HAC/FF1 output a 4 to 20 mA DC signal corresponding to the measured pres- sure, and also feature remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or µXL™ or HART® 275 host.
STANDARD SPECIFICATIONS
Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “0”.
PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil.
Reference Accuracy of Calibrated Span
(including the effects of zero-based linearity, hyster- esis, and repeatability, values are in absolute for EJA530A-DAS7N-02DN/HAC/FF1 )
FUNCTIONAL SPECIFICATIONS
Measurement Span and Range MPa psi (/D1) bar (/D3) kgf/cm2(/D4) A Span 10 to 200 kPa 1.45 to 29 0.1 to 2 0.1 to 2 Range 0 to 200 kPa 0 to 29 0 to 2 0 to 2 B Span 0.1 to 2 14.5 to 290 1 to 20 1 to 20 Range 0 to 2 0 to 290 0 to 20 0 to 20 C Span 0.5 to 10 72.5 to 1450 5 to 100 5 to 100 Range 0 to 10 0 to 1450 0 to 100 0 to 100 D Span 5 to 50 720 to 7200 50 to 500 50 to 500 Range 0 to 50 0 to 7200 0 to 500 0 to 500
Measurement Span and Range
MPa
psi (/D1)
bar (/D3)
kgf/cm2(/D4)
A
Span
10 to 200 kPa
1.45 to 29
0.1 to 2
Range
0 to 200 kPa
0 to 29
0 to 2
B
14.5 to 290
1 to 20
0 to 290
0 to 20
C
0.5 to 10
72.5 to 1450
5 to 100
0 to 10
0 to 1450
0 to 100
D
5 to 50
720 to 7200
50 to 500
0 to 50
0 to 7200
0 to 500
URL is defined as the Upper Range Limit from the table above.
MODEL AND SUFFIX CODES
Model
Suffix Codes
Description
EJA530A-DAS7N-02DN/HAC/FF1 EJA530A
. . . . . . . . . . . . . . . .
Absolute pressure transmitter
Gauge pressure transmitter
Output Signal
-D . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E) Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)
Measurement span
(capsule)
A . . . . . . . . . . . . . .
B . . . . . . . . . . . .
C . . . . . . . . . . . . .
D . . . . . . . . . . . . .
10 to 200 kPa {0.1 to 2 kgf/cm2} {1.45 to 29 psi} {0.1 to 2 bar}
0.1 to 2 MPa {1 to 20 kgf/cm2} {14.5 to 290 psi} {1 to 20 bar}
0.5 to 10 MPa {5 to 100 kgf/cm2} {72.5 to 1450 psi} {5 to 100 bar}
5 to 50 MPa {50 to 500 kgf/cm2} {720 to 7200 psi} {50 to 500 bar}
Wetted parts material *2
S# . . . . . . . . . . . . . . H# . . . . . . . . . . . . . .
[Process Connection] [Diaphragm] SUS316L *4 Hastelloy C-276 *3
Hastelloy C-276 *3 Hastelloy C-276 *3
Process connection
4 . . . . . . . . . .
7 . . . . . . . . . .
8 . . . . . . . . . .
9 . . . . . . . . . .
1/2 NPT female
1/2 NPT male
G 1/2 DIN 16 288 male
M20X1.5 DIN 16 288 male
N . . . . . . . .
Always N
-0 . . . . . . .
Always 0
Electrical connection
0 . . .
2 . . .
3 . . .
4 . . .
5 . .
7 . . .
8 . . .
9 . . .
A . . .
C . . .
D . . .
G1/2 female, one electrical connection
1/2 NPT female, two electrical connections without blind plug
Pg 13.5 female, two electrical connections without blind plug
M20 female, two electrical connections without blind plug
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
Pg 13.5 female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Integral indicator
E . . . N . . .
Digital indicator
Digital indicator with the range setting switch *1
(None)
Mounting bracket
E
F
L
N
SECC Carbon steel 2-inch pipe mounting
SUS304 2-inch pipe mounting
SUS316 2-inch pipe mounting
Optional codes
/口 Optional specification
The ‘’ marks indicate the most typical selection for each specification. Example: EJA530A-DAS7N-02DN/HAC/FF1 -DAS4N-02NN/口 The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details. *1: Not applicable for Output signal code F and G. *2: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. *3: Hastelloy C-276 or ASTM N10276. *4: SUS316L or ASTM grade 316L.
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel tekrachel@163.com
Add.: Room 2401 Building D Greenland Central Plaza, Science City, Huangpu District, Guangzhou 510663, Guangdong Province, China.