Product Information

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0[Product print page]

Product Name: Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0
Product Type: EJX115A-EMS2J-210DB-N00NN0
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0 is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. Yokogawa Low Flow Trans


 Detailed description

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0

Overview

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0 is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0 outputs a 4 to 20 mA DC signal corresponding to the measured flow. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.

STANDARD SPECIFICATIONS

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0

Refer to GS 01C25T02-01EN for Fieldbus communication type and GS 01C25T04-01EN for PROFIBUS PA communication type for the items marked with “◊.”

  SPAN AND RANGE LIMITS

Measurement span

F

Reference accuracy

X span

±0.04% of Span

X > span

±(0.015+0.01 URL/span)% of Span

X

2 kPa (8 inH2O)

URL

(upper range limit)

5 kPa (20 inH2O)

 PERFORMANCE SPECIFICATIONS

[Integral Orifice] Accuracy±5% of span

Refer to TI 01C20K00-01E for conditions. [Differential Pressure Transmitter]

Zero-based calibrated span, linear output, wetted parts material code S and silicone oil, unless otherwise mentioned.

For Fieldbus and PROFIBUS PA communication types, use calibrated range instead of span in the following specifications.

Specification Conformance

EJX series ensures specification conformance to at least ±3σ. 

MODEL AND SUFFIX CODES

Yokogawa Low Flow Transmitter EJX115A-EMS2J-210DB-N00NN0 

Model

Suffix Codes

Description

EJX115A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Low flow transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5 protocol)

4 to 20 mA DC with digital communication (HART 5 / HART 7 protocol) (Refer to GS 01C25T01-01EN)

Digital communication (FOUNDATION Fieldbus protocol, refer to

GS 01C25T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to GS 01C25T04-01EN)

Measurement span (capsule)

F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M . . . . . . . . . . . . . . . . . . . . . . . . . . . . H . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 to 5 kPa (4 to 20 inH2O)

2 to 100 kPa (8 to 400 inH2O)

20 to 210 kPa (80 to 840 inH2O)

Wetted parts material *1

S . . . . . . . . . . . . . . . . . . . . . . . . . . .

Cover flange and process connector: ASTM CF-8M # *2

Capsule: Hastelloy C-276 (Diaphragm) # *3   F316L SST, 316L SST (Others) #

Capsule gasket: Teflon-coated 316L SST Vent/Drain plug: 316 SST #   Orifice: 316 SST #

Manifold: F316 SST #   Spacer: 316 SST #   Orifice gasket: PTFE

Process connections

2 . . . . . . . . . . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . . . . . . . . . . .

Rc1/2 female

1/2 NPT female

Bolts and nuts material

J . . . . . . . . . . . . . . . . . . . . . . . G. . . . . . . . . . . . . . . . . . . . . . .

[For Cover flange]       [For Process connector]     [For Manifold] B7                B7                                          316L SST

316L SST                      316L SST                              316L SST

Installation

-2 . . . . . . . . . . . . . . . . . . . .

-3 . . . . . . . . . . . . . . . . . . . .

-6 . . . . . . . . . . . . . . . . . . . .

-7 . . . . . . . . . . . . . . . . . . . .

-8 . . . . . . . . . . . . . . . . . . . .

-9 . . . . . . . . . . . . . . . . . . . .

Vertical piping, right side high pressure, manifold upside Vertical piping, right side high pressure, manifold downside Vertical piping, left side high pressure, manifold upside

Vertical piping, left side high pressure, and manifold downside

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Amplifier housing

1 . . . . . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties*4

ASTM CF-8M stainless steel*5

Electrical connection

0 . . . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . .

7 . . . . . . . . . . . . . . . . .

9 . . . . . . . . . . . . . . . . . A . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*6

1/2 NPT female, two electrical connections and a blind plug*6

M20 female, two electrical connections and a blind plug*6

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

D . . . . . . . . . . . . . . . E . . . . . . . . . . . . . . . N . . . . . . . . . . . . . . .

Digital indicator*7

Digital indicator with the range setting switch (push button)*8

None

Mounting bracket

B . . . . . . . . . . . . . D . . . . . . . . . . . . . J . . . . . . . . . . . . . K . . . . . . . . . . . . . N . . . . . . . . . . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST 2-inch pipe mounting, L type (for vertical piping) None

-N . . . . . . . . . .

Always -N

00 . . . . . . . .

Always 00

N . . . . . . . .

Always N

N . . . . .

Always N

0 . . .

Always 0

Optional Codes

/¨ Optional specification

The “► marks indicate the most typical selection for each specification.

*1:      Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the users process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2:      Cast version of 316 SST. Equivalent to SCS14A.

*3:      Hastelloy C-276 or ASTM N10276.

*4:      Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less.

*5:      Not applicable for electrical connection code 0, 5, 7 and 9.

*6:      Material of a blind plug is aluminum alloy or 304 SST.

*7:      Not applicable for output signal code G.

*8:      Not applicable for output signal code F.

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.