Product Information

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN[Product print page]

Product Name: Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN
Product Type: EJA438W-EASA1CB-AA06-92NN
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN measure liquid, gas or steam pressure. Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN outputs a 4 to 20 mA DC signal.


 Detailed description

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN

 

OVERVIEW

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN

Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing assembly of the pressure transmitter. It is connected to the transmitter using capillary filled with fill fluid.
Models EJA438W-EASA1CB-AA06-92NN  Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas or steam pressure. They output a 4 to 20 mA DC signal corresponding to the measured pressure.
Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN feature remote setup and monitoring through communications with the model BT200/100 BRAIN TERMINAL, CENTUM CS/XL system etc.

 

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN

External Zero Adjustment “0”:
Continuously adjustable Resolution; 0.01 % of span
Zero Adjustment Limits:
Zero can be fully elevated or suppressed as long as low and high range values are within the measurement range low and high limits of the capsule.
Tag Plate:
JIS SUS304 or SUS316
Weight:
8.3 kg (18.3 lb) Model EJA438W-EASA1CB-AA06-92NN with 50 mm JIS 10K flange, capillary length 5 m; with integral indicator and mounting bracket.
13.4 kg (29.6 lb) Model EJA438N with 100 mm JIS 10K
flange, X2=100, capillary length 5 m; with integral indicator and mounting bracket.
Add 1.4 kg (3.1 lb) for JIS SCS14A stainless steel amplifier housing.
EMC  Conformity  Standards “0”: ,
EN61326-1 Class A, Table2 (For use in industrial locations) EN61326-2-3
European Pressure Equipment Directive 97/23/EC:
Sound Engineering Practice
Safety Requirement Standards:
EN61010-1
• Altitude of installation site: Max. 2,000 m above sea level
• Installation category: I
• Pollution degree: 2
• Indoor/Outdoor use

MODEL AND SUFFIX CODES

Yokogawa Transmitter EJA438W-EASA1CB-AA06-92NN

Model

Suffix Codes

Description

EJA438W-EASA1CB-AA06-92NN

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Diaphragm Sealed Gauge Pressure transmitter (Flush diaphragm type)

Output Signal

-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART protocol) *1

Digital communication (FOUNDATION Fieldbus protocol) *6

Digital communication (PROFIBUS PA protocol) *10

Measurement span

(capsule)

A . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0.06 to 3 MPa {0.6 to 30 kgf/cm2}{8.6 to 430 psi}{0.6 to 30 bar}

0.46 to 14 MPa {4.6 to 140 kgf/cm2}{66 to 2000 psi}{4.6 to 140 bar}

Wetted parts material *8

S# . . . . . . . . . . . . . . . . . . . . . . . . . . . . H# . . . . . . . . . . . . . . . . . . . . . . . . . . . . T . . . . . . . . . . . . . . . . . . . . . . . . . . . . U . . . . . . . . . . . . . . . . . . . . . . . . . . . .

[Diaphragm]                    [Others]

JIS SUS316L                  JIS SUS316L *11

Hastelloy C-276 *9      Hastelloy C-276 *9

Tantalum                          Tantalum

Titanium                           Titanium

Process flange rating

J1 . . . . . . . . . . . . . . . . . . . . . . . . . .

J2 . . . . . . . . . . . . . . . . . . . . . . . . . . J4 . . . . . . . . . . . . . . . . . . . . . . . . . . J6 . . . . . . . . . . . . . . . . . . . . . . . . . . A1 . . . . . . . . . . . . . . . . . . . . . . . . . . A2 . . . . . . . . . . . . . . . . . . . . . . . . . . A4 . . . . . . . . . . . . . . . . . . . . . . . . . . D2 . . . . . . . . . . . . . . . . . . . . . . . . . . D4 . . . . . . . . . . . . . . . . . . . . . . . . . . D5 . . . . . . . . . . . . . . . . . . . . . . . . . .

JIS 10K JIS 20K JIS 40K JIS 63K

ANSI Class 150          P1 . . . . . . . . . JPI Class 150

ANSI Class 300          P2 . . . . . . . . . JPI Class 300

ANSI Class 600          P4 . . . . . . . . . JPI Class 600

DIN PN10/16

DIN PN25/40

DIN PN64

Process flange                               

size / material

A . . . . . . . . . . . . . . . . . . . . . . . . .

B . . . . . . . . . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . . . . . . . . . . . . E . . . . . . . . . . . . . . . . . . . . . . . . . F . . . . . . . . . . . . . . . . . . . . . . . . .

2-inch (50 mm) / JIS S25C

2-inch (50 mm) / JIS SUS304 *12

2-inch (50 mm) / JIS SUS316 *13

3-inch (80 mm) / JIS S25C

3-inch (80 mm) / JIS SUS304 *12

3-inch (80 mm) / JIS SUS316 *13

Cover flange bolts material         

A . . . . . . . . . . . . . . . . . . . . . . .

B . . . . . . . . . . . . . . . . . . . . . . .

JIS SCM435

JIS SUS630

Fill fluid

 

-A *2 . . . . . . . . . . . . . . . . .

-B . . . . . . . . . . . . . . . . .

-C *3. . . . . . . . . . . . . . . . . .

-D *4 . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . .

[Process temp.]   [Ambient temp.] For general use (silicone oil)                           -10 to 250 oC    -10 to 60 oC For general use (silicone oil)                           -30 to 180 oC    -15 to 60 oC

.  For high temperature use (silicone oil)           10 to 300 oC     10 to 60 oC

For oil-prohibited use (fluorinated oil)           -20 to 120 oC    -10 to 60 oC For low temperature use (ethylene glycol)     -50 to 100 oC    -40 to 60 oC

A  . . . . . . . . . . . . . . . . .

Always A

Capillary length (m)

*5 . . . . . . . . . . . .

Specify capillary length from 1 to 10 m in . (Example for 2 m : 02)

Installation

-9 . . . . . . . . . . . . . .

Horizontal impulse piping type, left side high pressure

Electrical connection

 

0 . . . . . . . . . . . . .

2 . . . . . . . . . . . . .

3 . . . . . . . . . . . . .

4 . . . . . . . . . . . . .

5 . . . . . . . . . . . . .

7 . . . . . . . . . . . . .

8 . . . . . . . . . . . . .

9 . . . . . . . . . . . . . A . . . . . . . . . . . . . C . . . . . . . . . . . . . D . . . . . . . . . . . . .

G1/2 female, one electrical connection

1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M20 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug

1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M20 female, two electrical connections and a blind plug

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

 

D . . . . . . . . . .

E . . . . . . . . . . N . . . . . . . . . .

Digital indicator

Digital indicator with the range setting switch *7

(None)

Mounting bracket                                                                  

A . . . . . . . . .

B . . . . . . . . . J . . . . . . . . . N . . . . . . . . .

JIS SECC                    2-inch pipe mounting (flat type) JIS SUS304                 2-inch pipe mounting (flat type) JIS SUS316                 2-inch pipe mounting (flat type) (None)

Optional codes

/ Optional specification

The marks indicate the most typical selection for each specification. Example: EJA438W-DASA1AA-AA02-92NA/The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.

*1: Refer to GS 01C22T01-00E for HART Protocol version.
*2: In case of Wetted parts material code T (Tantalum), the process temperature limit is -10 to 200 oC.
*3: Wetted parts material code T (Tantalum) cannot be applied.
*4: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5.
*5: In case of Wetted parts material code H (Hastelloy C), T (Tantalum), and U (Titanium) or Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m.
*6: Refer to GS 01C22T02-00E for Fieldbus communication.
*7: Not applicable for Output signal code F and G.
*8: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to
plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*9: Hastelloy C-276 or ASTM N10276.
*10:    Refer to GS 01C22T03-00E for PROFIBUS PA communication.
*11:    JIS SUS316L or ASTM grade 316L.
*12:    JIS SUS304 or ASTM grade 304. Forged version may be used.
*13:    JIS SUS316 or ASTM grade 316. Forged version may be used.