Yokogawa Transmitter EJA438W-DASG2BA-AA03-90NN
OVERVIEW
Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing assembly of the pressure transmitter. It is connected to the transmitter using capillary filled with fill fluid. Models EJA438W-DASG2BA-AA03-90NN Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas or steam pressure. They output a 4 to 20 mA DC signal corresponding to the measured pressure. Yokogawa Transmitter EJA438W-DASG2BA-AA03-90NN feature remote setup and monitoring through communications with the model BT200/100 BRAIN TERMINAL, CENTUM CS/XL system etc.
External Zero Adjustment “0”: Continuously adjustable Resolution; 0.01 % of span Zero Adjustment Limits: Zero can be fully elevated or suppressed as long as low and high range values are within the measurement range low and high limits of the capsule. Tag Plate: JIS SUS304 or SUS316 Weight: 8.3 kg (18.3 lb) Model EJA438W-DASG2BA-AA03-90NN with 50 mm JIS 10K flange, capillary length 5 m; with integral indicator and mounting bracket. 13.4 kg (29.6 lb) Model EJA438N with 100 mm JIS 10K flange, X2=100, capillary length 5 m; with integral indicator and mounting bracket. Add 1.4 kg (3.1 lb) for JIS SCS14A stainless steel amplifier housing. EMC Conformity Standards “0”: , EN61326-1 Class A, Table2 (For use in industrial locations) EN61326-2-3 European Pressure Equipment Directive 97/23/EC: Sound Engineering Practice Safety Requirement Standards: EN61010-1 • Altitude of installation site: Max. 2,000 m above sea level • Installation category: I • Pollution degree: 2 • Indoor/Outdoor use
MODEL AND SUFFIX CODES
Model
Suffix Codes
Description
EJA438W-DASG2BA-AA03-90NN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diaphragm Sealed Gauge Pressure transmitter (Flush diaphragm type)
Output Signal
-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol) *1
Digital communication (FOUNDATION Fieldbus protocol) *6
Digital communication (PROFIBUS PA protocol) *10
Measurement span
(capsule)
A . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.06 to 3 MPa {0.6 to 30 kgf/cm2}{8.6 to 430 psi}{0.6 to 30 bar}
0.46 to 14 MPa {4.6 to 140 kgf/cm2}{66 to 2000 psi}{4.6 to 140 bar}
Wetted parts material *8
S# . . . . . . . . . . . . . . . . . . . . . . . . . . . . H# . . . . . . . . . . . . . . . . . . . . . . . . . . . . T . . . . . . . . . . . . . . . . . . . . . . . . . . . . U . . . . . . . . . . . . . . . . . . . . . . . . . . . .
[Diaphragm] [Others]
JIS SUS316L JIS SUS316L *11
Hastelloy C-276 *9 Hastelloy C-276 *9
Tantalum Tantalum
Titanium Titanium
Process flange rating
J1 . . . . . . . . . . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . . . . . . . . . . . J4 . . . . . . . . . . . . . . . . . . . . . . . . . . J6 . . . . . . . . . . . . . . . . . . . . . . . . . . A1 . . . . . . . . . . . . . . . . . . . . . . . . . . A2 . . . . . . . . . . . . . . . . . . . . . . . . . . A4 . . . . . . . . . . . . . . . . . . . . . . . . . . D2 . . . . . . . . . . . . . . . . . . . . . . . . . . D4 . . . . . . . . . . . . . . . . . . . . . . . . . . D5 . . . . . . . . . . . . . . . . . . . . . . . . . .
JIS 10K JIS 20K JIS 40K JIS 63K
ANSI Class 150 P1 . . . . . . . . . JPI Class 150
ANSI Class 300 P2 . . . . . . . . . JPI Class 300
ANSI Class 600 P4 . . . . . . . . . JPI Class 600
DIN PN10/16
DIN PN25/40
DIN PN64
Process flange
size / material
A . . . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . . . . . . . . . . . . E . . . . . . . . . . . . . . . . . . . . . . . . . F . . . . . . . . . . . . . . . . . . . . . . . . .
2-inch (50 mm) / JIS S25C
2-inch (50 mm) / JIS SUS304 *12
2-inch (50 mm) / JIS SUS316 *13
3-inch (80 mm) / JIS S25C
3-inch (80 mm) / JIS SUS304 *12
3-inch (80 mm) / JIS SUS316 *13
Cover flange bolts material
A . . . . . . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . . . . . . .
JIS SCM435
JIS SUS630
Fill fluid
-A *2 . . . . . . . . . . . . . . . . .
-B . . . . . . . . . . . . . . . . .
-C *3. . . . . . . . . . . . . . . . . .
-D *4 . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . .
[Process temp.] [Ambient temp.] For general use (silicone oil) -10 to 250 oC -10 to 60 oC For general use (silicone oil) -30 to 180 oC -15 to 60 oC
. For high temperature use (silicone oil) 10 to 300 oC 10 to 60 oC
For oil-prohibited use (fluorinated oil) -20 to 120 oC -10 to 60 oC For low temperature use (ethylene glycol) -50 to 100 oC -40 to 60 oC
A . . . . . . . . . . . . . . . . .
Always A
Capillary length (m)
口 口 *5 . . . . . . . . . . . .
Specify capillary length from 1 to 10 m in 口 口. (Example for 2 m : 02)
Installation
-9 . . . . . . . . . . . . . .
Horizontal impulse piping type, left side high pressure
Electrical connection
0 . . . . . . . . . . . . .
2 . . . . . . . . . . . . .
3 . . . . . . . . . . . . .
4 . . . . . . . . . . . . .
5 . . . . . . . . . . . . .
7 . . . . . . . . . . . . .
8 . . . . . . . . . . . . .
9 . . . . . . . . . . . . . A . . . . . . . . . . . . . C . . . . . . . . . . . . . D . . . . . . . . . . . . .
G1/2 female, one electrical connection
1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M20 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Integral indicator
D . . . . . . . . . .
E . . . . . . . . . . N . . . . . . . . . .
Digital indicator
Digital indicator with the range setting switch *7
(None)
Mounting bracket
A . . . . . . . . .
B . . . . . . . . . J . . . . . . . . . N . . . . . . . . .
JIS SECC 2-inch pipe mounting (flat type) JIS SUS304 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) (None)
Optional codes
/口 Optional specification
*1: Refer to GS 01C22T01-00E for HART Protocol version. *2: In case of Wetted parts material code T (Tantalum), the process temperature limit is -10 to 200 oC. *3: Wetted parts material code T (Tantalum) cannot be applied. *4: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *5: In case of Wetted parts material code H (Hastelloy C), T (Tantalum), and U (Titanium) or Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *6: Refer to GS 01C22T02-00E for Fieldbus communication. *7: Not applicable for Output signal code F and G. *8: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. *9: Hastelloy C-276 or ASTM N10276. *10: Refer to GS 01C22T03-00E for PROFIBUS PA communication. *11: JIS SUS316L or ASTM grade 316L. *12: JIS SUS304 or ASTM grade 304. Forged version may be used. *13: JIS SUS316 or ASTM grade 316. Forged version may be used.
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel tekrachel@163.com