Product Information

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3[Product print page]

Product Name: Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3
Product Type: EJA430A-EAS4A-99DA/KS2/D3
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3 measure liquid, gas, or steam pressure. Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3 outputs a 4 to 20 mA DC signal.


 Detailed description

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3

 

OVERVIEW

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3 

The high performance gauge pressure transmitter model EJA430A-EAS4A-99DA/KS2/D3 can be used to measure liquid, gas, or steam pressure.  It outputs a 4 to 20 mA DC signal corresponding  to the measured gauge pressure. Model EJA430A-EAS4A-99DA/KS2/D3 also features remote setup and monitoring through communications with the BRAIN™ terminal and  CENTUM CS™ or μXL™ or HART®  275 host.

 

PHYSICAL SPECIFICATIONS

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3 

Wetted Parts Materials
Diaphragm, Cover flange, Process connector, and Vent/Drain Plug
Refer to ‘MODEL AND SUFFIX CODE.’
Capsule Gasket
For wetted parts material code S, Teflon-coated
SUS316L.
For wetted parts material code other than S, PTFE(Teflon).
Process Connector Gasket
PTFE Teflon
Fluorinated rubber for Optional code /N2 and /N3
Non-wetted Parts Materials
Bolting
SCM435, SUS630, or SUH660
Housing
Low copper cast-aluminum alloy with polyurethane paint (Munsell 0.6GY3.1/2.0)
Degrees of Protection
IP67, NEMA4X
Cover O-rings
Buna-N, fluoro-rubber (optional)
Name plate and tag
SUS304 or SUS316 (option)
Fill Fluid
Silicone, Fluorinated oil (option)
Weight
3.9 kg (8.6 lbs.) without integral indicator, mounting bracket, and process connector.
Connections
Refer to the model code to specify the process and electrical connection type.
Process Connection of Cover Flange:
DIN 19213 with 7/16 inch x 20 unf female thread.

 

MODEL AND SUFFIX CODES

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3  

Model

Suffix Codes

Description

EJA430A-EAS4A-99DA/KS2/D3

. . . . . . . . . . . . . . . . . . . . . . . .

Gauge pressure transmitter

Output Signal

-D . . . . . . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . . . . .

-F . . . . . . . . . . . . . . . . . . . . . .

-G . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E)

Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)

Measurement span(capsule)

A . . . . . . . . . . . . . . . . . . . . .

B . . . . . . . . . . . . . . . . . . . . .

0.03 to 3 MPa {0.3 to 30 kgf/cm2} {4.3 to 430 psi} {0.3 to 30 bar}

0.14 to 14 MPa {1.4 to 140 kgf/cm2} {20 to 2000 psi} {1.4 to 140 bar}

Wetted parts material*9

S# . . . . . . . . . . . . . . . . . . . H# . . . . . . . . . . . . . . . . . . . M# . . . . . . . . . . . . . . . . . . . T . . . . . . . . . . . . . . . . . . . . A# . . . . . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . . . . . . . B# . . . . . . . . . . . . . . . . . . .

[Body]*1                                                          [Capsule]                      [Vent plug] SCS14A                                      SUS316L *2                           SUS316 *11

SCS14A                                      Hastelloy C-276 *3*10      SUS316 *11

SCS14A                                      Monel*3                                     SUS316 *11

SCS14A                                      Tantalum *3                            SUS316 *11

Hastelloy C-276 equivalent*4         Hastelloy C-276 *3*10      Hastelloy C-276*10

Hastelloy C-276 equivalent*4         Tantalum *3                            Hastelloy C-276*10

Monel equivalent*5                                Monel*3                                     Monel

Process connection

 

0 . . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . . .

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts material

 

A . . . . . . . . . . . . . . . . . B . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . .

[Maximum working pressure]

(A capsule)                         (B capsule)

SCM435            3 MPa {30 kgf/cm2}             14 MPa {140 kgf/cm2} SUS630            3 MPa {30 kgf/cm2}             14 MPa {140 kgf/cm2} SUH660            3 MPa {30 kgf/cm2}             14 MPa {140 kgf/cm2}

Installation

 

-2 . . . . . . . . . . . . . . .

-3 . . . . . . . . . . . . . . .

-6 . . . . . . . . . . . . . . .

-7 . . . . . . . . . . . . . . .

-8 . . . . . . . . . . . . . . .

-9 . . . . . . . . . . . . . . .

Vertical impulse piping type, right side high pressure, process connector upside*6

Vertical impulse piping type, right side high pressure, process connector downside*6

Vertical impulse piping type, left side high pressure, process connector upside*6

Vertical impulse piping type, left side high pressure, process connector downside*6

Horizontal impulse piping type, right side high pressure*7

Horizontal impulse piping type, left side high pressure*7

Electrical connection

 

0 . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . .

7 . . . . . . . . . . . . . . .

8 . . . . . . . . . . . . . . .

9 . . . . . . . . . . . . . . . A . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . .

G1/2 female, one electrical connection

1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M20 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug

1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M20 female, two electrical connections and a blind plug

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

 

D . . . . . . . . . . . . .

E . . . . . . . . . . . . . N . . . . . . . . . . . . .

Digital indicator

Digital indicator with the range setting switch*8

(None)

Mounting bracket                  

A . . . . . . . . . . . .

B . . . . . . . . . . . . J . . . . . . . . . . . . C . . . . . . . . . . . . D . . . . . . . . . . . . K . . . . . . . . . . . . N . . . . . . . . . . . .

SECC Carbon steel            2-inch pipe mounting (flat type) SUS304                              2-inch pipe mounting (flat type) SUS316                              2-inch pipe mounting (flat type) SECC Carbon steel            2-inch pipe mounting (L type) SUS304                              2-inch pipe mounting (L type) SUS316                              2-inch pipe mounting (L type) (None)

Optional codes

/ Optional specification

The marks indicate the most typical selection for each specification. Example: EJA430A-EAS4A-99DA/KS2/D3-DAS5A-92NA/

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of

SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.

 *1:      Indicates high pressure side cover flange and process connector material. Material of low pressure side cover flange

(open to atmosphere) is SCS14A.

*2:      Diaphragm material is Hastelloy C-276 or ASTM N10276. Other capsule wetted parts materials are SUSF316L, SUS316L or ASTM grade 316L.

*3:      Indicates diaphragm and other capsule wetted parts material.

*4:      Indicated material is equivalent to ASTM CW-12MW.

*5:      Indicated material is equivalent to ASTM M35-2.

*6:      If necessary, specify Mounting bracket code C, D or K.

*7:      If necessary, specify Mounting bracket code A, B or J.

*8:      Not applicable for Output signal code F and G.

*9:             Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*10:   Hastelloy C-276 or ASTM N10276.

*11:   SUS316 or ASTM grade 316.


OPTIONAL SPECIFICATIONS (For Explosion Protected types 0”)

 For FOUNDATION Fieldbus explosion protected type, see GS 01C22T02-00E. For PROFIBUS PA explosion protected type, see GS 01C22T03-00E.

Yokogawa Pressure Transmitter EJA430A-EAS4A-99DA/KS2/D3 

Item

Description

Code

Factory Mutual (FM)

FM Explosionproof Approval *1 *3 *4

Applicable standard: FM3600, FM3615, FM3810, ANSI/NEMA250

Explosionproof for Class I, Division 1, Groups B, C and D

Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Hazardous (classified) locations, indoors and outdoors (NEMA 4X) Temperature class: T6

Amb. Temp.: –40 to 60oC (–40 to 140oF)

FF1

FM Intrinsically safe Approval *1 *3 *4

Applicable standard: FM3600, FM3610, FM3611, FM3810, ANSI/NEMA250

Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1 Hazardous Locations.

Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2, Groups E, F & G, and Class III, Division 1 Hazardous Locations.

Enclosure: “NEMA 4X”,   Temp. Class: T4,  Amb. Temp.: –40 to 60oC (–40 to 140oF) Intrinsically Safe Apparatus Parameters

[Groups A, B, C, D, E, F and G]

Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 μH [Groups C, D, E, F and G]

Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 μH

FS1

Combined FF1 and FS1 *1 *3 *4

FU1

ATEX

ATEX FlameproofApproval *2 *4

Applicable standard: EN60079-0, EN60079-1

Certificate: KEMA 02ATEX2148

II 2G Ex d IIC T4, T5, T6

Amb. Temp.: T5; –40 to 80oC ( –40 to 176oF), T4 and T6; –40 to 75oC ( –40 to 167oF) Max. process Temp.: T4; 120oC (248oF), T5; 100oC (212oF), T6; 85oC (185oF)

KF21

ATEX Intrinsically safe Approval  *2 *3 *4

Applicable standard: EN50014, EN50020, EN50284

Certificate: KEMA 02ATEX1030X

II 1G EEx ia IIC T4,  Amb. Temp.: –40 to 60oC (–40 to 140oF) Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 μH

KS2

*1:      Applicable for Electrical connection code 2, 7 and C (1/2 NPT female).

*2:      Applicable for Electrical connection code 2, 4, 7, 9, C and D (1/2 NPT and M20 female).

*3:      Applicable for Output signal code D and E. T05-1E.EPS

For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD-400 is not applicable).

*4:      Lower limit of ambient temperature is –15˚C (5˚F) when /HE is specified.