Yokogawa Manual Setter YS1360-251
GENERAL
Yokogawa Manual Setter YS1360-251
The YS1360-251 is a manual setter that allows for manually output-ting operation signals to operation terminals. YS1360-251 include as standard an operation mode selector switch [cascade (C) and manual (M)], status input-based operation mode selector function, and opera- tion mode discrimination status output function.YS1360-251 offer high reliability thanks to Yokogawa’s proprietary technology, user friendliness, and expandability. The basic type conforming to the DIN short case size contributes to space saving for mounting, and complies with standards (CE, FM*, and CSA*). For easy replacement of earlier models requiring the same panel cutout dimensions and depth as those of earlier models are also offered. *: To be approved.
FEATURES
Yokogawa Manual Setter YS1360-251
● Display functions
(1) Display specification
The screen is divided into Operation Display, Tuning Dis- play, and Engineering Display groups, and functions can be set on the setting display for each function.
Hardware Specification
Yokogawa Manual Setter YS1360-251
● Input and output signal specification
Analog input sigal
|
Specification
|
1 to 5 VDC
|
2 points, PV input and cascade input
|
Input resistance
|
1 MΩ or more
|
Direct input (*1) (option)
|
One of the above 2 points (PV input)
possible
|
*1:Any one of mV,thermocouple, resisitance temperature detector potentiometer,2-wire transmitter,input isolator,or frequency input.
|
Model and Suffix Code
Yokogawa Manual Setter YS1360-251
Model
|
Suffix Code
|
Optional Code
|
Remark
|
YS1350
|
|
Manual setter for SV Setting
|
YS1360-251
|
|
Manual setter for MV Setting
|
Use
|
-1
|
YS1350: Always -1
YS1360-251: With hard manual unit
|
-2
|
YS1360 only: Without hard manual unit
|
Type
|
0
|
Basic type
|
2
|
YS100 compatible type (with YS100 case)
|
3
|
YS80 internal unit compatible type, EBS, I, EK, HOMAC compatible type (*1)
|
4
|
YS80 compatible type (YS 80 compatible size, YS100 terminal type)
|
5
|
100 Line compatible type (YS100 terminal type) (*2)
|
Power supply
|
0
|
100 VAC and 24 VDC common power supply
|
1
|
220 VAC power supply
|
Direct input (*3)
|
/A01
|
mV input
|
/A02
|
Thermocouple input
|
/A03
|
Resistance temperature detector input
|
/A04
|
Potentiometer input
|
/A05
|
Isolator
|
/A06
|
2-wire transmitter input (insulation type)
|
/A07
|
2-wire transmitter input (non-insulation type)
|
/A08
|
Frequency input
|
/DF
|
Direct input with Fahrenheit temperature range function (*9)
|
Communication
|
/A31
|
RS-485 communication (PC link, Modbus, YS protocol) (*4)
|
/A32
|
DCS-LCS communication (*5)
|
/A34
|
Ethernet communication (Modbus/TCP) (*6)
|
Certification
|
/FM
|
FM nonincendive approved (FM Class I, Division 2) (*7) (To be approved)
|
/CSA
|
CSA safety and nonincendive approved (Class I, Division 2) (*8) (To be approved)
|
|
|
|
|
|
|
*1: Can be connected with the YS80 housing (Model: SHUP-000). (The EK and HOMAC compatible housing SHUP-420 and EBS/I Series compatible hous-
ing SHUP-100 are available separately.)
*2: The 100 Line compatible housing (Model: YS006) is available separately.
*3: The direct input option can be added only for optional codes –x2x, -x4x, and -x5x. Multiple selections are not possible.
*4: A combination with suffix code “-x3x” is not possible. Optional codes /A31 and /A32 cannot be simultaneously specified.
Please specify the communication options /A31 (RS-485 communication) to directly communicate with the CENTUM CS3000/VP.
*5: Optional codes /A31 and /A32 cannot be simultaneously specified. Please specify the communication options /A32 (DCS-LCS communication) to com-
municate with the CENTUM CS3000/VP through the SCIU.
*6: Communication option /A34 can be specified only for suffix code –x0x.
*7: Can be added only for suffix code –x0x.
*8: Can be added only for suffix code –x0x and –x2x.
*9 This option can be combined only with option code /A02 or /A03.If option code /DF is specified, Fahrenheit temperature range can be available for direct input range in addition to Centigrade temperature range. In case of specifying Fahrenheit temperature range for direct input, option code /DF is required. When the direct input temperature range may be changed to Fahrenheit temperature range after shipment, also specify option code /DF.