Product Information

Yokogawa Program Controller UP55A-100-11-00[Product print page]

Product Name: Yokogawa Program Controller UP55A-100-11-00
Product Type: UP55A-100-11-00
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Program Controller UP55A-100-11-00 employs an easy-to- read, 14-segment large color LCD display, along with navigation keys. Yokogawa Program Controller UP55A-100-11-00


 Detailed description

Yokogawa Program Controller UP55A-100-11-00


 Overview

Yokogawa Program Controller UP55A-100-11-00

The UP55A-100-11-00 program controller employs an easy-to- read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. A ladder sequence function is included as standard. The short depth of the controller helps save instrument panel space. The UP55A-100-11-00 also support open networks such as Ethernet communication.


 Features

Yokogawa Program Controller UP55A-100-11-00

• A 14-segment, active (PV display color changing function) color LCD display is employed.
Two five-digit, high-resolution displays are possible. Alphabet letters can be displayed in an easy-to-read manner.
The guide display shows parameter names.
• Easy to operate
Navigation keys (SET/ENTER and Up/Down/Left/ Right arrow keys) are employed to facilitate making settings.
• 65 mm depth
The small depth enables the mounting in a thin and small instrumented panel.
• Ladder sequence function is included as standard. This function allows for creating a simple sequence control. Dedicated LL50A Parameter Setting Software (sold separately) allows for performing programming using a ladder language.
• Various built-in open network functions such as
Ethernet are available.
Easy connection with various vendors’ PLCs is possible.
• Quick setting function
Setting only the minimum necessary parameters for operation is possible. (For single-loop control only)
• Equipped with a multitude of functions
Universal I/O and eight control modes (cascade control, etc) are included as standard. PID control, heating/cooling control, feed forward control, etc. are available.


Construction, Installation, and Wiring

Yokogawa Program Controller UP55A-100-11-00

• Material: Polycarbonate (Flame retardancy: UL94V-0)
• Case color: White (Light gray) or Black (Light
Charcoal gray)
• Weight: 0.5 kg or less
• External dimensions (mm): 96 (W) × 96 (H) × 65 (depth from the panel face)
(Depth except the projection on the rear panel)
• Installation: Direct panel mounting; mounting bracket, one each for upper and lower mounting
• Panel cutout dimensions (mm): 92+0.8/0 (W) × 92+0.8/0 (H)
• Mounting attitude: Up to 30 degrees above the horizontal. No down
• Dust-proof and drip-proof: IP66 (for front panel) (Not available for side-by-side close mounting.)
ward titling allowed.
• Wiring: M3 screw terminal with square washer (for signal wiring and power wiring)
 

Model and Suffix Code

Yokogawa Program Controller UP55A-100-11-00

 

Model

 

Suffix code

Optional suffix code

 

Description

 

UP55A-100-11-00

 

 

Program Controller (provided with retransmission output or 15 V DC loop power supply, 8 DIs, and 8 DOs) (Power supply: 100-240 V AC)

30 program patterns / 300 program segments (Max. 99 segments per pattern)

 

Type 1:

Basic control

-0

 

 

 

 

 

 

Standard type

-1

 

 

 

 

 

 

Position proportional type

-2

 

 

 

 

 

 

Heating/cooling type

 

 

 

Type 2: Functions (*1)

0

 

 

 

 

 

None

1

 

 

 

 

 

Remote (1 additional aux. analog) input, 1 additional DI

2

 

 

 

 

 

RS-485 communication (Max.19.2 kpbs, 2-wire/4-wire)

3

 

 

 

 

 

10 additional DOs

4

 

 

 

 

 

3 additional aux. analog inputs, 2 DIs and 5 DOs to be deleted

 

 

 

 

Type 3:

Open networks

0

 

 

 

 

None

1

 

 

 

 

RS-485 communication (Max.38.4 kbps, 2-wire/4-wire)

2

 

 

 

 

Ethernet communication (with serial gateway function)

3

 

 

 

 

CC-Link communication (with Modbus master function)

4

 

 

 

 

PROFIBUS-DP communication (with Modbus master function)

5

 

 

 

 

DeviceNet communication (with Modbus master function)

 

 

Display language (*2)

-1

 

 

 

English

-2

 

 

 

German

-3

 

 

 

French

-4

 

 

 

Spanish

 

Case color

0

 

 

White (Light gray)

1

 

 

Black (Light charcoal gray)

Fixed code

-00

 

Always “-00

 

 

 

Optional suffix codes

 

/DR

Additional direct input (TC and 3-wire/4-wire RTD) and current input to Remote (1 additional aux. analog) input, 1 DI to be deleted (*3)

/HA

Heater break alarm (*4)

/DC

Power supply 24 V AC/DC

/CT

Coating (*5)

*1: When “3” is specified for the Type 2 code, only “0” can be specified for the Type 3 code.
*2: English, German, French, and Spanish can be displayed as the guide display.
*3: When any of “1” or “4” is specified for the Type 2 code, the /DR option can be specified.
*4: When “-0” is specified for the Type 1 code, the /HA option can be specified.
*5: When the /CT option is specified, the UP55A-100-11-00 does not conform to the safety standards (UL and CSA) and CE marking.