Yokogawa Program Controller UP35A-110-11-00
Overview
The UP35A-110-11-00 program controller employs an easy-to- read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. A ladder sequence function is included as standard. The short depth of the controller helps save instrument panel space. The UP35A-110-11-00 also support open networks such as Ethernet communication.
Features
• A 14-segment, active (PV display color changing function) color LCD display is employed.
Heater Break Alarm Specifications
• Number of inputs: 2 • Number of outputs: 2 (transistor contact output) • Use: Measures the heater current using an external current transformer (CT) and generates a heater break alarm when the measured value is less than the break detection value. • Current transformer input resistance: About 9.4 Ω • Current transformer input range: 0.0 to 0.1 Arms (0.12 Arms or more cannot be applied.) • Heater current setting range: OFF, 0.1 to 300.0 Arms Heater current measured value display range: 0.0 to 360.0 Arms Note: The CT ratio can be set. CT ratio setting range: 1 to 3300 • Recommended CT: CT from U.R.D., Ltd. CTL-6-S-H: CT ratio 800, measurable current range: 0.1 to 80.0 Arms CTL-12L-30: CT ratio 3000, measurable current range: 0.1 to 180.0 Arms • Heater current measurement period: 200 ms • Heater current measurement accuracy: ±5% of current transformer input range span ± 1digit (CT error is not included.) • Heater current detection resolution: Within 1/250 of current transformer input range span • Break detection On-time: Min. 0.2 second (for time proportional output) • Weight: 0.5 kg or less • External dimensions (mm): 96 (W) × 96 (H) × 65 (depth from the panel face) (Depth except the projection on the rear panel) • Installation: Direct panel mounting; mounting bracket, one each for upper and lower mounting • Panel cutout dimensions (mm): 92+0.8/0 (W) × 92+0.8/0 (H) • Mounting attitude: Up to 30 degrees above the horizontal. No downward titling allowed. • Wiring: M3 screw terminal with square washer (for signal wiring and power wiring)
Model and Suffix Codes
Model
Suffix code
Optional suffix code
Description
UP35A-110-11-00
Program Controller (provided with retransmission output or 15 V DC loop power supply, 3 DIs, and 3 DOs) (Power supply: 100-240 V AC)
2 program patterns/20 program segments (Max. 20 segments per pattern)
Type 1:
Basic control
-0
Standard type
-1
Position proportional type
-2
Heating/cooling type
Type 2: Functions
0
None
1
5 additional DIs, 5 additional DOs
Type 3:
Open networks
RS-485 communication (Max.38.4 kbps, 2-wire/4-wire)
2
Ethernet communication (with serial gateway function)
3
CC-Link communication (with Modbus master function)
4
PROFIBUS-DP communication (with Modbus master function)
5
DeviceNet communication (with Modbus master function)
Display language (*1)
English
German
-3
French
-4
Spanish
Case color
White (Light gray)
Black (Charcoal gray light)
Fixed code
-00
Always “-00”
Optional suffix codes
/AP
2 additional patterns/20 additional segments
/HA
Heater break alarm (*2)
/DC
Power supply 24 V AC/DC
/CT
Coating (*3)
*1: English, German, French, and Spanish can be displayed as the guide display.
*2: The /HA option can be specified when the Type 1 code is "-0" or "-2." *3: When the /CT option is specified, the UP35A-110-11-00 does not conform to the safety standards (UL and CSA) and CE marking.