Yokogawa Program Controller UP35A
Overview
The UP35A program controller employs an easy-to- read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. A ladder sequence function is included as standard. The short depth of the controller helps save instrument panel space. The UP35A also support open networks such as Ethernet communication.
Features
• A 14-segment, active (PV display color changing function) color LCD display is employed.
Heater Break Alarm Specifications
• Number of inputs: 2 • Number of outputs: 2 (transistor contact output) • Use: Measures the heater current using an external current transformer (CT) and generates a heater break alarm when the measured value is less than the break detection value. • Current transformer input resistance: About 9.4 Ω • Current transformer input range: 0.0 to 0.1 Arms (0.12 Arms or more cannot be applied.) • Heater current setting range: OFF, 0.1 to 300.0 Arms Heater current measured value display range: 0.0 to 360.0 Arms Note: The CT ratio can be set. CT ratio setting range: 1 to 3300 • Recommended CT: CT from U.R.D., Ltd. CTL-6-S-H: CT ratio 800, measurable current range: 0.1 to 80.0 Arms CTL-12L-30: CT ratio 3000, measurable current range: 0.1 to 180.0 Arms • Heater current measurement period: 200 ms • Heater current measurement accuracy: ±5% of current transformer input range span ± 1digit (CT error is not included.) • Heater current detection resolution: Within 1/250 of current transformer input range span • Break detection On-time: Min. 0.2 second (for time proportional output) • Weight: 0.5 kg or less • External dimensions (mm): 96 (W) × 96 (H) × 65 (depth from the panel face) (Depth except the projection on the rear panel) • Installation: Direct panel mounting; mounting bracket, one each for upper and lower mounting • Panel cutout dimensions (mm): 92+0.8/0 (W) × 92+0.8/0 (H) • Mounting attitude: Up to 30 degrees above the horizontal. No downward titling allowed. • Wiring: M3 screw terminal with square washer (for signal wiring and power wiring)
Model and Suffix Code
Model
Suffix code
Optional suffix code
Description
UP35A
Program Controller (provided with retransmission output or 15 V DC loop power supply, 3 DIs, and 3 DOs) (Power supply: 100-240 V AC)
2 program patterns/20 program segments (Max. 20 segments per pattern)
Type 1:
Basic control
-0
Standard type
-1
Position proportional type
-2
Heating/cooling type
Type 2: Functions
0
None
1
5 additional DIs, 5 additional DOs
Type 3:
Open networks
RS-485 communication (Max.38.4 kbps, 2-wire/4-wire)
2
Ethernet communication (with serial gateway function)
3
CC-Link communication (with Modbus master function)
4
PROFIBUS-DP communication (with Modbus master function)
5
DeviceNet communication (with Modbus master function)
Display language (*1)
English
German
-3
French
-4
Spanish
Case color
White (Light gray)
Black (Charcoal gray light)
Fixed code
-00
Always “-00”
Optional suffix codes
/AP
2 additional patterns/20 additional segments
/HA
Heater break alarm (*2)
/DC
Power supply 24 V AC/DC
/CT
Coating (*3)
*1: English, German, French, and Spanish can be displayed as the guide display.
*2: The /HA option can be specified when the Type 1 code is "-0" or "-2." *3: When the /CT option is specified, the UP35A does not conform to the safety standards (UL and CSA) and CE marking.