Yokogawa Temperature Transmitter YTA70, head mount type, thermocouple, RTD, ohm, or DC milivolt input Yokogawa Temperature Transmitter YTA70, HART communication protocol


 Detailed description

Yokogawa Temperature Transmitter YTA70

The Yokogawa Temperature Transmitter YTA70 is a head mount type of temperature transmitter that accepts thermocouple, RTD, ohm, or DC milivolt input and converts it to a 4 to 20mA DC signal for transmission. The Yokogawa Temperature Transmitter YTA70 conforms to the standard DIN formB head mounting. The Yokogawa Temperature Transmitter YTA70 supports HART communication protocol.


YTA50 YTA70 Temperature Transmitter.jpg


Features

Yokogawa Temperature Transmitter YTA70

Outstanding performance

Microprocessor-based sensing technology ensures high accuracy and stability.


Variety of sensor inputs

The type of sensor input is user-selectable: thermocouples, RTDs, ohms, or DC milivolt.


Digital communication

The Yokogawa Temperature Transmitter YTA70 supports HART communication protocol.


Specifications

Yokogawa Temperature Transmitter YTA70

Accuracy (typical) YTA50: ±0.1% of span or ±0.2deg C(0.36deg F)
YTA70: ±0.1% of span or ±0.1deg C(0.18deg F)
Cold junction Compensation accuracy (For T/C only)
±1 deg C (1.8 deg F)
Power supply effect ±0.005% of FS per volt
Ambient temperature effect YTA50: (±0.1% or ±0.1deg C) / 10 deg C
YTA70: (±0.05% or ±0.05deg C) / 10 deg C
Input signal Single input
Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt
Output Two wire 4 to 20 mA DC
Supply voltage 7 to 35 V DC
(7 to 28 V DC for Intrinsically safe type)
Ambient temperature Option code may affect limits
-40 to 85 0C (-40 to 185 0F)
Mounting DIN form B head mounting
Weight 50g (0.11lb)
Certificates CENELEC or FM



Models and Suffix Codes

Yokogawa Temperature Transmitter YTA70

Model Suffix code Descriptions
YTA70 • • • • • • • • • • Temperature Transmitter (Head Mount Type)
Output Signal - E • • • • • • 4 to 20mA DC with digital communication (HART protocol)
Optional Specifications / KS2 CENELEC ATEX (KEMA) Intrinsically safe approval Applicable standard: EN 60079-0: 2006, EN 60079-11: 2007, EN 60079-26: 2007, EN 61241-0: 2006, EN 61241-11: 2006 Certificate: KEMA 06 ATEX0191 II1G Ex ia IIC T4 or T6, II1D Ex iaD Amb. temp. for gas-proof T4: -40 to 85 C (-40 to 185 F), T6: -40 to 60 C (-40 to 140 F) Surface temp. for dust-proof: T4: T105 C amb. temp. -40 to 85 C (-40 to 185 F) T6: T85 C amb. temp. -40 to 60 C (-40 to 140 F) Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W, Ci=1nF, Li=10 H Sensor circuit: Uo=9.6V, Io=25mA, Po=60mW, Co=2.4 F, Lo=33mH
/ DS2 FM intrinsically safe/Nonincendive and CENELEC ATEX intrinsically safe approval combination (For CENELEC ATEX Intrinsically safe approval, see /KS2) [FM Intrinsically safe/Nonincendive approval] Applicable standard: FM 3600, FM 3610, FM 3611, FM 3810 Intrinsically safe for Class I, Division 1, Groups A, B, C, and D Supply : Vmax=28V, Imax=120mA, Pmax=0.84W, Ci 1nF, Li 10 H Nonincendive for Class I, Division 2, Groups A, B, C, D Hazardous (Classified) indoor/outdoor (TYPE 4) Locations Supply: Vmax=35V, Imax=150mA, Ci=0 F, Li=10 H Amb. temp.: T6 Ta=55 C, T4 Ta=80 C
/ SS2 IECEx intrinsically safe, FM intrinsically safe/Nonincendive, and CENELEC ATEX (KEMA) intrinsically safe approval combination (For FM and CENELEC ATEX intrinsically safe approval, see /KS2 and /DS2.) [IECEx intrinsically safe approval] Applicable standard: IEC 60079-0:2007-10, IEC 60079-11:2006, IEC 60079-26:2006, IEC 61241-11:2005 Certificate: IECEx KEM 10.0086 Ex ia IIC T4...T6 Ga, Ex ia IIIC T135 °C...T80 °C Da Amb. temp.: -40 to 85°C (-40 to 185°F) for T4, -40 to 45°C (-40 to 113°F) for T6 Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W, Ci=1nF, Li=10 µH Sensor circuit: Uo=9.6V, Io=28mA, Po=67mW, Co=3.5µF, Lo=35mH