Product Information

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22[Product print page]

Product Name: Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22
Product Type: EJX110A-EMS4G-917DB/KU22
Exhibitors: Yokogawa
Product Documentation: No Related Documents

Brief

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22, single crystal silicon resonant sensor, measure liquid, gas, or steam flow as well as liquid level, density and pressure


 Detailed description

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22


The high performance Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22 features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. 

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22 outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. 

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22, its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. 

All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.


STANDARD SPECIFICATIONS

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22
L Capsule M Capsule H Capsule V Capsule
Range -40 to 40 inH2O -400 to 400 inH2O -2000 to 2000 inH2O -71 to 2000 psi
Span 0.4 to 40 inH2O 2 to 400 inH2O 10 to 2000 inH2O 10 to 2000 psi
Accuracy ±0.04% ±0.04% ±0.04% ±0.04%
Accuracy (*Note) ±0.025% * ±0.025% * ±0.025% *
Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
Certificates FM, CENELEC ATEX, CSA, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus, 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC
(10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC
(9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO)
Ambient temperature -40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
Process temperature -40 to 120 deg C (-40 to 248 deg F) (general use type)
Maximum working pressure 2300 psi 3600 psi
Mounting 2-inch pipe mounting
Wetted parts material Capsule 316L SST(Diaphragm material is Hastelloy C-276),
Hastelloy C-276,Tantalum, Monel
Cover flange ASTM CF-8M, Hastelloy C-276, Monel
Housing Cast aluminum alloy or ASTM CF-8M stainless steel (optional)


*Certain conditions apply refer to GS for more information 


MODEL AND SUFFIX CODES

Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22

Model

Suffix Codes

Description

EJX110A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Differential pressure transmitter

Output signal

-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 to 20 mA DC with digital communication (BRAIN protocol)

4 to 20 mA DC with digital communication (HART 5 protocol)

4 to 20 mA DC with digital communication (HART 5/HART 7 protocol) (Refer to GS 01C25T01-01EN)

Digital communication (FOUNDATION Fieldbus protocol, refer to

GS 01C25T02-01EN)

Digital communication (PROFIBUS PA protocol, refer to

GS 01C25T04-01EN)

Measurement span (capsule)

F . . . . . . . . . . . . . . . . . . . . . . . . . . .


L . . . . . . . . . . . . . . . . . . . . . . . . . . . .


M . . . . . . . . . . . . . . . . . . . . . . . . . . . 

H . . . . . . . . . . . . . . . . . . . . . . . . . . .

V . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0.1 to 5 kPa (0.4 to 20 inH2O) (For Wetted parts material code S)

0.1 to 10 kPa (0.4 to 40 inH2O) (For Wetted parts material code M, H, T, AD and B)

0.5 to 100 kPa (2 to 400 inH2O)

2.5 to 500 kPa (10 to 2000 inH2O)

0.07 to 14 MPa (10 to 2000 psi)

Wetted parts material *1

¨ . . . . . . . . . . . . . . . . . . . . . . . .

Refer to Wetted Parts Material Table.

Process connections

 

 

 

0 . . . . . . . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . . . . . . . .

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts materia

J . . . . . . . . . . . . . . . . . . .

G. . . . . . . . . . . . . . . . . . .

C . . . . . . . . . . . . . . . . . . . .

B7 carbon steel

316L SST

660 SST

Installation

 

-7 . . . . . . . . . . . . . . . .

-8 . . . . . . . . . . . . . . . .

-9 . . . . . . . . . . . . . . . .

-B . . . . . . . . . . . . . . . .

-U . . . . . . . . . . . . . . . .

Vertical piping, left side high pressure, and process connection downside

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Bottom Process Connection, left side high pressure*2*3

Universal flange*2

Amplifier housing

1 . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . .

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties*4

ASTM CF-8M stainless steel*5

Electrical connection

0 . . . . . . . . . . . .

2 . . . . . . . . . . . .

4 . . . . . . . . . . . .

5 . . . . . . . . 

7 . . . . . . .

9 . . . . . . .


 A . . . . . . . . . . . .


C . . . . . . . . . .


D . . . . . . . . . . . .

G1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*6

1/2 NPT female, two electrical connections and a blind plug*6

M20 female, two electrical connections and a blind plug*6

G1/2 female, two electrical connections and a SUS316 blind plug

1/2 NPT female, two electrical connections and a SUS316 blind plug

M20 female, two electrical connections and a SUS316 blind plug

Integral indicator

 

D . . . . . . .

E . . . . . . .

N . . . . . . . .

Digital indicator*7

Digital indicator with the range setting switch (push button)*8

None

Mounting bracket                                   ►

B . . . .

D . . . .

J . . . .

K . . . .

M . . . . .....

N . . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting (for bottom process connection type

None

Optional Codes

/ Optional specification


The “►” marks indicate the most typical selection for each specification.

*1:      Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2:      Only applicable for Wetted parts material code S.

*3:      Not applicable for measurement span code F.

*4:      Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less.

*5:      Not applicable for electrical connection code 0, 5, 7 and 9.

*6:      Material of a blind plug is aluminum alloy or 304 SST.

*7:      Not applicable for output signal code G.

*8:      Not applicable for output signal code F.


Table. Wetted Parts Materials for Yokogawa Differential Pressure Transmitter EJX110A-EMS4G-917DB/KU22

Wetted parts material code

Cover flange and process connector

 

Capsule

 

Capsule gasket

 

Vent/Drain plug

 

S #

 

ASTM CF-8M *1

Hastelloy C-276 *2 (Diaphragm) F316L SST, 316L SST (Others)

 

Teflon-coated 316L SST

 

316 SST

H #

ASTM CF-8M *1

Hastelloy C-276 *2

PTFE Teflon

316 SST

M #

ASTM CF-8M *1

Monel

PTFE Teflon

316 SST

T

ASTM CF-8M *1

Tantalum

PTFE Teflon

316 SST

A #

Hastelloy C-276 equivalent *3

Hastelloy C-276 *2

PTFE Teflon

Hastelloy C-276 *2

D #

Hastelloy C-276 equivalent *3

Tantalum

PTFE Teflon

Hastelloy C-276 *2

B #

Monel equivalent *4

Monel

PTFE Teflon

Monel

*1:      Cast version of 316 SST. Equivalent to SCS14A.

*2:      Hastelloy C-276 or ASTM N10276.

*3:      Indicated material is equivalent to ASTM CW-12MW.

*4:      Indicated material is equivalent to ASTM M35-2.