Manufacturer: Yokogawa Electric Corporation
Yokogawa Transmitter EJX110A-FMB5G-919DN/KS26/D4/N4/M01/T1
The high performance Yokogawa Transmitter EJX110A-FMB5G-919DN/KS26/D4/N4/M01/T1 features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.
Yokogawa Transmitter EJX110A-FMB5G-919DN/KS26/D4/N4/M01/T1 outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.
Yokogawa Transmitter EJX110A-FMB5G-919DN/KS26/D4/N4/M01/T1 its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.
All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
MODEL AND SUFFIX CODES
Model Suffix Codes Description EJX110A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential pressure transmitter Output signal -D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol) 4 to 20 mA DC with digital communication (HART 5 protocol) 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol) (Refer to GS 01C25T01-01EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C25T02-01EN) Digital communication (PROFIBUS PA protocol, refer to GS 01C25T04-01EN) Measurement span (capsule) F . . . . . . . . . . . . . . . . . . . . . . . . . . . . L . . . . . . . . . . . . . . . . . . . . . . . . . . . . M . . . . . . . . . . . . . . . . . . . . . . . . . . . H . . . . . . . . . . . . . . . . . . . . . . . . . . . . V . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 to 5 kPa (0.4 to 20 inH2O) (For Wetted parts material code S) 0.1 to 10 kPa (0.4 to 40 inH2O) (For Wetted parts material code M, H, T, A, D and B) 0.5 to 100 kPa (2 to 400 inH2O) 2.5 to 500 kPa (10 to 2000 inH2O) 0.07 to 14 MPa (10 to 2000 psi) Wetted parts material *1 ¨ . . . . . . . . . . . . . . . . . . . . . . . . Refer to “Wetted Parts Material” Table. Process connections ► 0 . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . . . . . . 5 . . . . . . . . . . . . . . . . . . . . . . without process connector (Rc1/4 female on the cover flanges) with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector without process connector (1/4 NPT female on the cover flanges) Bolts and nuts materia J . . . . . . . . . . . . . . . . . . . . G. . . . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . . . . B7 carbon steel 316L SST 660 SST Installation ► -7 . . . . . . . . . . . . . . . . -8 . . . . . . . . . . . . . . . . -9 . . . . . . . . . . . . . . . . -B . . . . . . . . . . . . . . . . -U . . . . . . . . . . . . . . . . Vertical piping, left side high pressure, and process connection downside Horizontal piping and right side high pressure Horizontal piping and left side high pressure Bottom Process Connection, left side high pressure*2*3 Universal flange*2 Amplifier housing 1 . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . Cast aluminum alloy Cast aluminum alloy with corrosion resistance properties*4 ASTM CF-8M stainless steel*5 Electrical connection ► 0 . . . . . . . . . . . . 2 . . . . . . . . . . . . 4 . . . . . . . . . . . . 5 . . . . . . . . 7 . . . . . . . 9 . . . . . . . . A . . . . . . . . . . . . C . . . . . . . . . . D . . . . . . . . . . . . G1/2 female, one electrical connection without blind plugs 1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*6 1/2 NPT female, two electrical connections and a blind plug*6 M20 female, two electrical connections and a blind plug*6 G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M20 female, two electrical connections and a SUS316 blind plug Integral indicator ► D . . . . . . . E . . . . . . . N . . . . . . . . Digital indicator*7 Digital indicator with the range setting switch (push button)*8 None Mounting bracket ► B . . . . D . . . . J . . . . K . . . . M . . . . ..... N . . . . . 304 SST 2-inch pipe mounting, flat type (for horizontal piping) 304 SST 2-inch pipe mounting, L type (for vertical piping) 316 SST 2-inch pipe mounting, flat type (for horizontal piping) 316 SST 2-inch pipe mounting, L type (for vertical piping) 316 SST 2-inch pipe mounting (for bottom process connection type) None Optional Codes / Optional specification
Model
Suffix Codes
Description
EJX110A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential pressure transmitter
Output signal
-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART 5 protocol)
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol) (Refer to GS 01C25T01-01EN)
Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C25T02-01EN)
Digital communication (PROFIBUS PA protocol, refer to
GS 01C25T04-01EN)
Measurement span (capsule)
F . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.1 to 5 kPa (0.4 to 20 inH2O) (For Wetted parts material code S)
0.1 to 10 kPa (0.4 to 40 inH2O) (For Wetted parts material code M, H, T, A, D and B)
0.5 to 100 kPa (2 to 400 inH2O)
2.5 to 500 kPa (10 to 2000 inH2O)
0.07 to 14 MPa (10 to 2000 psi)
Wetted parts material *1
¨ . . . . . . . . . . . . . . . . . . . . . . . .
Refer to “Wetted Parts Material” Table.
Process connections
►
0 . . . . . . . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . . . . . . . .
without process connector (Rc1/4 female on the cover flanges)
with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector
without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts materia
J . . . . . . . . . . . . . . . . . . . .
G. . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . .
B7 carbon steel
316L SST
660 SST
Installation
-7 . . . . . . . . . . . . . . . .
-8 . . . . . . . . . . . . . . . .
-9 . . . . . . . . . . . . . . . .
-B . . . . . . . . . . . . . . . .
-U . . . . . . . . . . . . . . . .
Vertical piping, left side high pressure, and process connection downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Bottom Process Connection, left side high pressure*2*3
Universal flange*2
Amplifier housing
1 . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . .
Cast aluminum alloy
Cast aluminum alloy with corrosion resistance properties*4
ASTM CF-8M stainless steel*5
Electrical connection
0 . . . . . . . . . . . .
2 . . . . . . . . . . . .
4 . . . . . . . . . . . .
5 . . . . . . . .
7 . . . . . . .
9 . . . . . . . .
A . . . . . . . . . . . .
C . . . . . . . . . .
D . . . . . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections and a blind plug*6
1/2 NPT female, two electrical connections and a blind plug*6
M20 female, two electrical connections and a blind plug*6
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Integral indicator
D . . . . . . .
E . . . . . . .
N . . . . . . . .
Digital indicator*7
Digital indicator with the range setting switch (push button)*8
None
Mounting bracket ►
B . . . .
D . . . .
J . . . .
K . . . .
M . . . . .....
N . . . . .
304 SST 2-inch pipe mounting, flat type (for horizontal piping)
304 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting, flat type (for horizontal piping)
316 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting (for bottom process connection type)
Optional Codes
/ Optional specification
Contact Number: +86 13724889019 Email: tekrachel2024@163.com Web: www.tek-international.com WeChat: tekrachel